High Pressure Crucible – from 25 to 500 µL and up to 22 Mpa
high pressure crucible

High Pressure Crucibles for Thermal Analysis

Hermetically sealed high pressure crucible up to 10 Mpa

 

High Pressure Crucible

Crucibles for Thermal Analysis

Crucibles serve as containers for samples during thermoanalytical measurements. They guarantee tha...

Crucibles for Thermal Analysis

Crucibles serve as containers for samples during thermoanalytical measurements. They guarantee that the sensor is not contaminated by the measurement. The type of crucible used for a measurement can have a large effect on the quality of the results obtained, and in addition, also influences important characteristics of the DSC measuring cell. Considering the relevant factors before the measurement can often help to save time later on when interpreting the curve.

Features and benefits:

  • Large volume – increases the sensitivity
  • Low mass – pushes the resolution to the limit
  • Purity – no interaction of the sample with the crucible
  • Material – guarantees high thermal conductivity and form stability
  • Flatness – ensures perfect thermal contact and no artifacts

 

Choosing the right crucible guarantees the best results

The following criteria have a significant influence for selecting the right crucible:

  • TGA or DSC analysis
  • Temperature range
  • Sample
  • Sample changer
  • Atmosphere
  • crucible mass
  • crucible volume

Extremely Wide Crucible Range

 

 


 
high pressure crucible
high pressure crucible
high pressure crucible
high pressure crucible

Products and Specs

 
Products and Specs
Filter:
Set filter
Clear All
 
{searchattributeslabels/Search CapacityLabel}
Quantity
Volume μL
Pin
Lid
Medium pressure crucible
{searchattributeslabels/Search CapacityLabel}
Quantity 25
Volume μL 120
Pin with
Lid with
Material No.: 00026929
Quantity25
Volume μL120
Pinwith
Lidwith
Sealing toolA3
Suitable forDSC
Medium pressure crucible
{searchattributeslabels/Search CapacityLabel}
Quantity 25
Volume μL 120
Pin without
Lid with
Material No.: 00029990
Quantity25
Volume μL120
Pinwithout
Lidwith
Sealing toolA3
Suitable forDSC/sample robot
High pressure crucible
{searchattributeslabels/Search CapacityLabel}
Quantity 3
Volume μL 30
Pin without
Lid with
Material No.: 51140404
Quantity3
Volume μL30
Pinwithout
Lidwith
Sealing toolB
Suitable forDSC/sample robot
High pressure crucible gold plated
{searchattributeslabels/Search CapacityLabel}
Quantity 3
Volume μL 30
Pin without
Lid with
Material No.: 51140405
Quantity3
Volume μL30
Pinwithout
Lidwith
Sealing toolB
Suitable forDSC/sample robot
Seal for high pressure crucible
{searchattributeslabels/Search CapacityLabel}
Quantity 60
Volume μL
Pin
Lid
Material No.: 51140403
Quantity60
High pressure crucible small
{searchattributeslabels/Search CapacityLabel}
Quantity 25
Volume μL 25
Pin without
Lid with
Material No.: 30077139
Quantity25
Volume μL25
Pinwithout
Lidwith
Sealing toolD
Suitable forDSC/sample robot
High pressure crucible
{searchattributeslabels/Search CapacityLabel}
Quantity 25
Volume μL 40
Pin without
Lid with
Material No.: 00026731
Quantity25
Volume μL40
Pinwithout
Lidwith
Sealing toolD
Suitable forDSC/sample robot
High pressure crucible
{searchattributeslabels/Search CapacityLabel}
Quantity 25
Volume μL 40
Pin with
Lid with
Material No.: 00026732
Quantity25
Volume μL40
Pinwith
Lidwith
Sealing toolD
Suitable forDSC
High pressure crucible
{searchattributeslabels/Search CapacityLabel}
Quantity 1
Volume μL 270
Pin with
Lid with
Material No.: 00650072
Quantity1
Volume μL270
Pinwith
Lidwith
Sealing toolC
Suitable forF
High pressure crucible
{searchattributeslabels/Search CapacityLabel}
Quantity 1
Volume μL 500
Pin with
Lid with
Material No.: 00650066
Quantity1
Volume μL500
Pinwith
Lidwith
Sealing toolC
Suitable forF
Burst Disk (Seal)
{searchattributeslabels/Search CapacityLabel}
Quantity 1
Volume μL
Pin
Lid
Material No.: 00027216
Quantity1
Suitable for00650072/00650066
Comparison

Documentation

Brochures

STARe Excellence Software Brochure
Thermal analysis is a well-established analytical method that is widely used in many different fields. It provides laboratories with valuable results...
Crucibles for Thermal Analysis Brochure
Crucibles serve as containers for samples during thermoanalytical measurements. They guarantee that the sensor is not contaminated by the measurement....

Datasheets

The MultiSTAR® DSC Sensor Family Datasheet
The sensor is the heart of any DSC measuring cell. Ideally a modern DSC sensor should be very sensitive, have a fast response, a baseline that is abso...
DSC-Chemiluminescence System Datasheet
The high-pressure DSC-CL combination has the potential to replace the traditional timeconsuming oven aging tests in the prescreening phase of novel po...
DSC-Microscopy System Datasheet
The system provides images of samples at predefined temperature or time intervals. A further evaluation possibility is to quantify color differences b...
DSC-Photocalorimetry System Datasheet
The photocalorimeter accessory is used in combination with the METTLER TOLEDO DSC 1 or DSC82xe and extends the application possibilities of DSC into t...

Services

+44 116 234 0484
Call Service

Explore our Services - Tailored to Fit your Equipment

We support and service your measurement equipment through its entire lifecycle, from installation to preventive maintenance and calibration to equipment repair.

Thank you for visiting www.mt.com. We have tried to optimize your experience while on the site, but we noticed that you are using an older version of a web browser. We would like to let you know that some features on the site may not be available or may not work as nicely as they would on a newer browser version. If you would like to take full advantage of the site, please update your web browser to help improve your experience while browsing www.mt.com.