Load Cell and Loading Cell | Load Cell Sensor | Dynamic Load Cell | 50 kg Load Cell
Load Cell, Weigh Module, Load Sensor

Load Cell, Weigh Module, Load Sensor

Robust precision weigh modules and electronic load cells with all globally required approvals and standards.

Load Cell and Weigh Module / Loading Cell Definition

What is a load cell and how does it work? The basics of load cell technology is converting a load - which is a force applied to any mass in the ea...

What is a load cell and how does it work?
The basics of load cell technology is converting a load - which is a force applied to any mass in the earth gravity field – into an electrical signal. Most load cells have so called load cell sensors that convert a mechanical strain into a resistant change. Learn more on load cell sensors below. The mass applies a load enforced by the gravity field, that load stresses the body of the load cell and lead to deformation – strain. The load cell sensor is converted into resistant change and finally into a voltage output. That output is proportional to the applied mass.

A scale load cell, or load cell sensor, is used in variety of industries in which precise measurements are needed. Load cells accurately measure the weight of tanks, vessels, hoppers or conveyors. Load cells are built to withstand the demands of a variety of rugged industrial applications. The capacity of load cells can greatly vary. Some load cells are more appropriate for laboratory applications, while others are more appropriate for high-capacity batches or logistics applications.

Load cells shall meet all globally-required approvals and standards. They include electronic load cells, analog load cells and hydraulic load cells that allow you to change your structure into a scale. Load cells are used in floor scales, belt weighers, weighing systems, pallet scales, checkweigher scales, load cell scales and conveyor scales. Loading cell technology from METTLER TOLEDO features robustness for harsh environments as well. These are typically used in tank scales, vessel weighing, silo scales and truck weighing.

How do you design a load cell?
Their form first distinguishes load cells. Single-point load cells are used for small and mid-size applications. Strain gauge load cells are used for floor scales and mid-size tank scales. Canister load cells are used for heavy-capacity applications. Another separation criteria for load cell types and uses is the output provided. Analog load cells need an external terminal for amplification and A/D conversion while digital load cells or electronic load cells have in-built "intelligence" with the advantage of better accuracy, much more robust data transfer and the potential to monitor the condition of the load cell to help with maintenance. All load cells have a different load cell price, depending on the performance needed. Irrespectively of design and price, you can buy load cells of any kind at METTLER TOLEDO.

How accurate are load cells?
Very often accuracy and resolution are mixed when talking about load cells. Resolution is how many digits are displayed, but more digits does not mean better accuracy. Accuracy describes how true the weighing results are (load cell accuracy calculation and load cell capacity calculation). For good reason, legal-for-trade scale load cells limit resolution to eliminate getting into the interpretation of results. Therefore, the best benchmarks for accuracy are legal-for-trade approvals. Load cell sensors typically provide accuracy from 1/3,000d up to 1/10,000d (also referred to in the load cell specifications). Load cells using force restoration reach 1/200,000 or even better. Under ideal conditions, which include constant temperature and humidity, the accuracy can be 5-10 times better.
But it is fairly complicated to calculate the final system accuracy of a load cell load cell scales. Many impacts like temperature, time, resolution etc. need to be considered. It is recommended to seek advice from load cell manufacturers. The Weighing Component Selector is providing these calculations in a professional manner.

How do load cells fail?
Load cells failures can have multiple reasons. Most common source of failures are junction boxes in analog load cell systems. If such an analog load cell system fails, the troubleshooting can be cumbersome, because every load cell cable, load cell and the load cell junction box needs to be checked. Digital load cells eliminate this and many other sources of failures by providing diagnostic data. By processing the data you can be sure, your system is up and running and in case a load cell fails, the system will tell you which load cell is not responding.

How is load cell measured?
Load cells are used to measure the weight of any possible material (e.g. with a 50 kg load cell, 10 ton load cell, load cell 50 ton, load cell 100 ton or any other capacity). They reach from microgram in load cell sensors to several load cell 100 tons in high capacity load cell scales. Low weights are required for pharma applications where fractions of a gram can make a key difference. Mid-size load cells are typically used for processing and trading materials (e.g. 5 ton load cell). Large capacities are used for storage applications.

How do I connect to a load cell?
Load cells measure both the dead load and the net load of a load cell scale, so this needs to be considered when calculating scale load cell capacity. How the goods are positioned on the scale also matters. Using load cells that are larger than they need to be for a given application is not recommended as accuracy suffers. For scales where the goods are mostly centered — which is true for most tank, silo and vessel scales — the formula is:
C >= sf*(TDL+SC)/N (eg. tank scales)

For scales with four load cells where the goods are likely to be positioned off-center — which is true for floor, small truck and conveyor scales — the formula is:
C >= sf*(TDL/4 + SC/2)  (eg. floor, small vehicle scales, conveyors)

C = LC or Weigh module capacity
TDL = Total dead load
SC = Scale capacity
sf = Safety factor (typically 1.25)
N = Number of load cells or weigh modules

Seek professional consulting for more complicated systems.
More details you can find in the Weigh Module Systems Engineering Handbook addressing engineering topics.

How do I install load cells?
A common problem for using load cells is to choose the wrong protection. Load cells are very sensitive to humidity and regular wash-down. Although claiming high IP rating the protection is not good for damp heat. When it comes to high humidity and sudden temperature changes (cold environment, hot wash-down) it is advised to always choose stainless steel hermetically sealed load cells. So different parameters need to be taken into account when you buy load cells.

Calibration costs for load cell systems are often underestimated. If your quality system requires regular calibrations of such weighing systems, seek advice for the most efficient method by METTLER TOLEDO. An ISO9001 complying method needs an independent calibration equipment traceable to international standards. Under no circumstances, it can be assumed that calibration is never changing and a load cell scale does not need re-calibration at all.  An efficient method calibrating larger tanks scales is RapidCal™.

Installing a load cell scale is often under estimated on accuracy impact. In any case shielded cables are recommended since the load cell signal in very low voltage and easily disturbed. Chose the shortest cables possible as copper changes resistance over temperature and the lower cable resistance, the better.
Very often the integration of scale load cells is cumbersome and requires engineering knowledge. Weigh Modules are higher integrated, provide safety and ideal load conditions for the load cell. See details how to select the right Weigh Modules and find the right load cell for sale. 

What is the difference between load cell and strain gauge?
Strain gauges are components of load cells. Load cells are a counterforce that converts load into strain. That strain is taken by the load cell sensor, which changes its resistance into an electrical quantity that can be measured and reported as a weighing result. This is the same principle for 10 ton load cell and load cell 100 ton.

What is the purpose of a load cell?
Load cells measure force, sadly not masses which would be ideal. That leads to the fact that any other vertical accidentally occurring force in a load cell scales has direct impact on the accuracy. Typically piping forces in a vessel, contact to ground by eg. debris collection, cable touching for loading cells and small capacity systems, vertical vibration etc. are to mention. Touch base with expert to avoid those problems in your system and find the right load cell for sale.

What is load cell sensitivity?
The sensitivity of the load cell scale is often critical. A filling process is more accurate the higher the update rate is. Same is true for a batching system where the recipe is more reparative the more sensitive the scale load cell measures. Sensitivity comes a little costs, but can make a huge difference.

What is the output of load cell? How do you calculate load cell output?
Most load cells provide an analog output of 2-3 mV/V. Since these are passive devices, they need an external power source for excitation. The output signal varies related to the relative excitation voltage and current load. Thus, it is crucial to have a very stable excitation source that eliminates effects cause by the power source. A 2mV/V load cell provides as little as 20mV output at full capacity when powered with 10V output. Modern terminals (load cell reader) provide both a stable power source and accurate amplification of the output signal to convert results into digital information. It is important for the signal to perform proper load cell wiring.

What is excitation voltage for a load cell?
Load cells are passive devices that need an external power source for excitation. Related to that excitation, voltage can change based on the current load, causing errors. Therefore, it is crucial to have a very stable excitation source to eliminate errors caused by the power source. Modern terminals provide a stable power source, accurate amplification of the small output signal, and conversion of results into digital information.

What is hydraulic load cell?
Hydraulic load cells use the principle of pressure change when loading an enclosed fluid. The pressure change is measured by a pressure transducer. Hydraulic load cells are not very accurate and not very common these days. The advantage of robustness that they offered in times when electronics were not as accurate are long gone.

Are load cells linear?
Typically load cells are very linear to 0.03% or even much better. Scales today are primarily only calibrated at zero and a maximum span point indicating that the range in-between is linear.

How many load cells do I need? Would 1 or 2 load cells be sufficient for a 3 or 4 leg tank scale?
Using fewer load cells than tank legs is possible for liquid level control systems. The key is to ensure that the center of gravity in the system does not shift horizontally with load. Accuracy for such a system may not be ideal. Do not use such a system for bulk material.

Will a PT1000 or PT100 electronic work with analoge load cells?
Analog load cells have a mV/V interface which is different from passive temperature sensors such as PT100, PT100, thus special electronics is required.

How do you calibrate a load cell?
Load cell sensors need to be calibrated  where they will be used. The primary reason for onsite calibration is that gravity changes by location. A load cell manufactured in location A and used in location B would create an error without onsite calibration. Another reason onsite calibration is important is the ongoing wear on the device itself to which all technical instruments are subject. Depending on the importance of accuracy in the process in which the scale is used, it is good practice to calibrate a scale every 1-2 years.

What is digital load cell? How do digital load cells work?
Digital POWERCELL® load cells inside PowerMount™ weigh modules feature an onboard processor that provides condition monitoring and immediately adjusts to environmental changes. POWERCELL® digital load cells ensures accurate weighing regardless of the effects of vibration and temperature, assisting machine and equipment builders in maximizing the output value for their customers.

What is a load cell for weighing machine?
A scale load cell for weighing machine is used in variety of industries in which precise measurements are needed. Load cells for weighing machines accurately measure the weight of tanks, vessels, hoppers or conveyors. Load cell technology is built to withstand the demands of a variety of rugged industrial applications. The capacity of load cells for weighing machines can greatly vary. Some load cells are more appropriate for laboratory applications, while others are more appropriate for high-capacity batches or logistics applications.

Load cells for weighing machines shall meet all globally-required approvals and standards. They include single-ended beam load cells that allow you to change your structure into a scale. Beam load cells are used in multiples in floor scales, belt weighers, weighing systems, pallet scales, checkweigher scales and conveyor scales.. Canister/ring load-cell technology features robustness for harsh environments as well. These are typically used in tank scales, vessel weighing, silo scales and truck weighing.


Compression Load Cell / Weigh Modules
Tension Weigh Modules
Strain Gauge Load Cell / S Type Load Cell
Single Point Load Cell

Compression Load Cell / Weigh Modules

Tension Weigh Modules

Strain Gauge Load Cell / S Type Load Cell

Single Point Load Cell

Weigh modules enable quick and safe conversion of tanks, hoppers and conveyors into a scale. Built-in features ensure that safety, performance and precision are maintained.
Tension Weigh modules enable the safe conversion of suspended tanks and hoppers into a scale. Built-in features ensure that safety, performance and precision are maintained.
Strain gauge load cells are used in multiples (typically 3 or 4) in weighing systems, tank scales and conveyor scales.
Single point load cells are used individually in weighing systems, bench scales and filling and packaging machines.
For floor supported tanks, hoppers, silos
Tanks on concrete or steel foundation
Wide capacity range
From 5kg up to 300t per weigh module
Versatile usage for most industries
Various materials, IP69K versions, wide rang of accessories
Reliable Performance
Global approvals, Ex versions, Built-in safety
PowerMount versions
Load Cell diagnostics, superior accuracy, RunFlat
Wide capacity range
5kg .. 10t (11lb .. 22klb)
For suspended hoppers and vessels
Hoppers suppended from above
Wide capacity range
Based on S-Type laod cells from 5kg up to 10t
Ideal for mid size containers
Extremely easy to integrate weighing
Reliable Performance
Global approvals, Ex versions
Wide capacity range
5kg .. 4.4t (11lb .. 10klb)
For mid-size weighing systems
Process tanks, floor scales etc.
Stainess Steel version
Food and Pharma usage
PowerCell versions
For extreme accuracy requirements
Reliable Performance
Global approvals, Ex versions, IP69K
Wide capacity range
3kg .. 2000kg (6.6lb .. 4400lb)
For small weighing systems
Bench scales, filling, dosing, packaging etc.
Stainess Steel Versions with up to IP69K protection
Food and Pharma usage
Global Standards provided as standard
E.g. OIML, NTEP, FM, ATEX
Canister Load Cell / Ring Load Cell
Tension Load Cell / Load Cell Tension
Load cell junction box

Canister Load Cell / Ring Load Cell

Tension Load Cell

Load Cell Junction Box

Canister and ring load cells are used in tank and vessel scales, hopper scales, silo scales, vehicle scales and rail scales.
Tension load cells are used in suspended weighing systems such as hanging hoppers, vessels and tanks.
METTLER TOLEDO's analog precision junction boxes are suitable for quick and simple connection of multiple analog load cells to a terminal.
Wide capacity range
0.25t .. 300t (0.55klb .. 660klb)
For heavy capacity weighing systems
Tank-, silo-, hopper-, vehicle scales
Coping with harsh environments
Stainess Steel, IP69K versions
For best reliability
PowerCell versions
Global Performance
Global approvals, Ex versions
Wide capacity range
25kg .. 10t (50lb .. 22kllb)
For suspended weighing systems
Hoppers, vessels, bulkweigher etc.
Stainess Steel Versions with up to IP67 protection
Food and Pharma usage
Global Standards provided as standard
e.g., FM, ATEX, OIML, NTEP
Exceptional Stability
Discrete resistors - not trim pots
Stable and easy to adjust
By means of rotary dip switches
Cope with harsh environments
316 Stainess Steel and IP69K versions available
Global Standards
E.g., ATEX, GMP, NSF versions
Compression Load Cell / Weigh Modules

Weigh modules enable quick and safe conversion of tanks, hoppers and conveyors into a scale. Built-in features ensure that safety, performance and precision are maintained.

Tension Weigh Modules

Tension Weigh modules enable the safe conversion of suspended tanks and hoppers into a scale. Built-in features ensure that safety, performance and precision are maintained.

Strain Gauge Load Cell / S Type Load Cell

Strain gauge load cells are used in multiples (typically 3 or 4) in weighing systems, tank scales and conveyor scales.

Single Point Load Cell

Single point load cells are used individually in weighing systems, bench scales and filling and packaging machines.

Canister Load Cell / Ring Load Cell

Canister and ring load cells are used in tank and vessel scales, hopper scales, silo scales, vehicle scales and rail scales.

Tension Load Cell / Load Cell Tension

Tension load cells are used in suspended weighing systems such as hanging hoppers, vessels and tanks.

Load cell junction box

METTLER TOLEDO's analog precision junction boxes are suitable for quick and simple connection of multiple analog load cells to a terminal.

Services

+34 90 232 0023
Call Service
Uptime
Support & Repair
Performance
Maintenance & Optimization
Compliance
Calibration & Quality
Expertise
Training & Consulting

Publications

Extensive Know-How for Weigh Modules, Load Cells and Load Sensors

Scale Design Handbook for Engineers
Evaluating Measuring Methods for Filling
Weighing for Process Vessel and Reactors
Weigh Modules Provide More Than Accuracy
Best Inventory Control in Tanks and Silos
Dos and Don'ts for Custom Scale Design and Weigh Module Installation

Video

Thank you for visiting www.mt.com. We have tried to optimize your experience while on the site, but we noticed that you are using an older version of a web browser. We would like to let you know that some features on the site may not be available or may not work as nicely as they would on a newer browser version. If you would like to take full advantage of the site, please update your web browser to help improve your experience while browsing www.mt.com.