$ EZ-EDS Version 3.27.1.20191218 Generated Electronic Data Sheet $ **************************************************************************** $ METTLER TOLEDO $ **************************************************************************** $ $ Product: IND360 Premium $ $ (c) Copyright 2020 Mettler-Toledo AG. All Rights Reserved. $ $ Author: Wang xiaolin (POLC) $ Date: 07.16.2020 $ $ **************************************************************************** $ $ ATTENTION: $ Changes in this file can cause configuration or communication problems. $ $ **************************************************************************** $ $ Changes: $ Version Date Name SVN Description $ 1.0 07.16.2020 Wang xiaolin 6869 Initial Version $ 1.1 07.28.2020 Wang xiaolin 8169 Using EDS tool V3.27 to fix some warnings. $ Modified the Min/Max/Defasult value of Param73 from 104 to 100. $ Deleted the paramN and assemblyN related 1-block format $ Modified the Catalog in [Device[ region from "MT-IND360 2 Ports" to "MT-IND360" $ **************************************************************************** [File] DescText = "EDS-File for IND360 Transmitter"; CreateDate = 07-28-2020; CreateTime = 13:37:56; ModDate = 07-28-2020; ModTime = 13:37:57; Revision = 1.1; HomeURL = "www.mt.com"; 1_IOC_Details_License = 0xEDC6689B; [Device] VendCode = 666; VendName = "METTLER TOLEDO"; ProdType = 12; ProdTypeStr = "Communications Adapter"; ProdCode = 16898; MajRev = 1; MinRev = 1; ProdName = "IND360"; Catalog = "MT-IND360"; [Device Classification] Class1 = EtherNetIP; [Params] Param1 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xCA, $ Data Type 4, $ Data Size in bytes "MB1 Command Value", $ name "", $ units "Floating point value - optionally used with command", $ help string -3000000000.0,3000000000.0,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param2 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xD2, $ Data Type 2, $ Data Size in bytes "MB1 Channel Mask", $ name "", $ units "Channel Mask (0 always for single devices)", $ help string 0,0xFFFF,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Enum2 = 0,"Apply command to Channel 1", 1,"Apply command to Channel 2", 2,"Apply command to Channel 3", 3,"Apply command to Channel 4", 4,"Apply command to Channel 5", 5,"Apply command to Channel 6", 6,"Apply command to Channel 7", 7,"Apply command to Channel 8", 8,"Apply command to Channel 9", 9,"Apply command to Channel 10", 10,"Apply command to Channel 11", 11,"Apply command to Channel 12", 12,"Apply command to Channel 13", 13,"Apply command to Channel 14", 14,"Apply command to Channel 15", 15,"Apply command to Channel 16"; Param3 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC7, $ Data Type 2, $ Data Size in bytes "MB1 Command", $ name "", $ units "Command and Channel Indicator", $ help string 0,32767,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param4 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC7, $ Data Type 2, $ Data Size in bytes "SB1 Reserved 1", $ name "", $ units "Reserved", $ help string 0,32767,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param5 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC7, $ Data Type 2, $ Data Size in bytes "SB1 Reserved 2", $ name "", $ units "Reserved", $ help string 0,32767,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param6 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC7, $ Data Type 2, $ Data Size in bytes "SB1 Reserved 3", $ name "", $ units "Reserved", $ help string 0,32767,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param7 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC7, $ Data Type 2, $ Data Size in bytes "SB1 Command", $ name "", $ units "Status Command and Channel Indicator", $ help string 0,32767,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param8 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0010, $ Descriptor 0xCA, $ Data Type 4, $ Data Size in bytes "MB1 Measuring Value", $ name "", $ units "Requested floating point value (32-bit)", $ help string -3000000000.0,3000000000.0,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param9 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0010, $ Descriptor 0xD2, $ Data Type 2, $ Data Size in bytes "MB1 Device Status", $ name "", $ units "Command Status", $ help string 0,0xFFFF,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Enum9 = 0,"Sequence bit 0", 1,"Sequence bit 1", 2,"Heart Beat", 3,"Data Okay", 4,"Alarm Condition", 5,"Center of Zero", 6,"Motion", 7,"Net Mode", 8,"Alternate Weight Unit", 9,"Device Specific Bit 1", 10,"Device Specific Bit 2", 11,"Device Specific Bit 3", 12,"Device Specific Bit 4", 13,"Device Specific Bit 5", 14,"Device Specific Bit 6", 15,"Device Specific Bit 7"; Param10 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0010, $ Descriptor 0xC7, $ Data Type 2, $ Data Size in bytes "MB1 Response", $ name "", $ units "Field Value and Channel Indicator", $ help string 0,32767,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param11 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0010, $ Descriptor 0xD2, $ Data Type 2, $ Data Size in bytes "SB1 Status Group 1", $ name "", $ units "Status Group 1", $ help string 0,32767,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param12 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0010, $ Descriptor 0xD2, $ Data Type 2, $ Data Size in bytes "SB1 Status Group 2", $ name "", $ units "Status Group 2", $ help string 0,32767,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param13 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0010, $ Descriptor 0xD2, $ Data Type 2, $ Data Size in bytes "SB1 Status Group 3", $ name "", $ units "Status Group 3", $ help string 0,32767,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param14 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0010, $ Descriptor 0xC7, $ Data Type 2, $ Data Size in bytes "SB1 Response", $ name "", $ units "Field Value and Channel Indicator", $ help string 0,32767,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places $ Measuring block 2 output $ Measuring block 2 output Param15 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xCA, $ Data Type 4, $ Data Size in bytes "MB2 Command Value", $ name "", $ units "Floating point value - optionally used with command", $ help string -3000000000.0,3000000000.0,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param16 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xD2, $ Data Type 2, $ Data Size in bytes "MB2 Channel Mask", $ name "", $ units "Channel Mask (0 always for single devices)", $ help string 0,0xFFFF,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param17 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC7, $ Data Type 2, $ Data Size in bytes "MB2 Command", $ name "", $ units "Command and Channel Indicator", $ help string 0,32767,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places $ Measuring block 2 input $ Measuring block 2 input Param18 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0010, $ Descriptor 0xCA, $ Data Type 4, $ Data Size in bytes "MB2 Measuring Value", $ name "", $ units "Requested floating point value (32-bit)", $ help string -3000000000.0,3000000000.0,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param19 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0010, $ Descriptor 0xD2, $ Data Type 2, $ Data Size in bytes "MB2 Device Status", $ name "", $ units "Command Status", $ help string 0,0xFFFF,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param20 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0010, $ Descriptor 0xC7, $ Data Type 2, $ Data Size in bytes "MB2 Response", $ name "", $ units "Field Value and Channel Indicator", $ help string 0,32767,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places $ Measure block 3 output $ Measure block 3 output Param21 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xCA, $ Data Type 4, $ Data Size in bytes "MB3 Command Value", $ name "", $ units "Floating point value - optionally used with command", $ help string -3000000000.0,3000000000.0,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param22 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xD2, $ Data Type 2, $ Data Size in bytes "MB3 Channel Mask", $ name "", $ units "Channel Mask (0 always for single devices)", $ help string 0,0xFFFF,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param23 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC7, $ Data Type 2, $ Data Size in bytes "MB3 Command", $ name "", $ units "Command and Channel Indicator", $ help string 0,32767,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places $ Measureing block 3 input $ Measureing block 3 input Param24 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0010, $ Descriptor 0xCA, $ Data Type 4, $ Data Size in bytes "MB3 Measuring Value", $ name "", $ units "Requested floating point value (32-bit)", $ help string -3000000000.0,3000000000.0,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param25 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0010, $ Descriptor 0xD2, $ Data Type 2, $ Data Size in bytes "MB3 Device Status", $ name "", $ units "Command Status", $ help string 0,0xFFFF,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param26 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0010, $ Descriptor 0xC7, $ Data Type 2, $ Data Size in bytes "MB3 Response", $ name "", $ units "Field Value and Channel Indicator", $ help string 0,32767,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places $ Measure block 4 output $ Measure block 4 output Param27 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xCA, $ Data Type 4, $ Data Size in bytes "MB4 Command Value", $ name "", $ units "Floating point value - optionally used with command", $ help string -3000000000.0,3000000000.0,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param28 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xD2, $ Data Type 2, $ Data Size in bytes "MB4 Channel Mask", $ name "", $ units "Channel Mask (0 always for single devices)", $ help string 0,0xFFFF,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param29 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC7, $ Data Type 2, $ Data Size in bytes "MB4 Command", $ name "", $ units "Command and Channel Indicator", $ help string 0,32767,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places $ Measureing block 4 input $ Measureing block 4 input Param30 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0010, $ Descriptor 0xCA, $ Data Type 4, $ Data Size in bytes "MB4 Measuring Value", $ name "", $ units "Requested floating point value (32-bit)", $ help string -3000000000.0,3000000000.0,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param31 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0010, $ Descriptor 0xD2, $ Data Type 2, $ Data Size in bytes "MB4 Device Status", $ name "", $ units "Command Status", $ help string 0,0xFFFF,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param32 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0010, $ Descriptor 0xC7, $ Data Type 2, $ Data Size in bytes "MB4 Response", $ name "", $ units "Field Value and Channel Indicator", $ help string 0,32767,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places $ Measure block 5 output $ Measure block 5 output Param33 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xCA, $ Data Type 4, $ Data Size in bytes "MB5 Command Value", $ name "", $ units "Floating point value - optionally used with command", $ help string -3000000000.0,3000000000.0,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param34 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xD2, $ Data Type 2, $ Data Size in bytes "MB5 Channel Mask", $ name "", $ units "Channel Mask (0 always for single devices)", $ help string 0,0xFFFF,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param35 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC7, $ Data Type 2, $ Data Size in bytes "MB5 Command", $ name "", $ units "Command and Channel Indicator", $ help string 0,32767,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places $ Measureing block 5 input $ Measureing block 5 input Param36 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0010, $ Descriptor 0xCA, $ Data Type 4, $ Data Size in bytes "MB5 Measuring Value", $ name "", $ units "Requested floating point value (32-bit)", $ help string -3000000000.0,3000000000.0,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param37 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0010, $ Descriptor 0xD2, $ Data Type 2, $ Data Size in bytes "MB5 Device Status", $ name "", $ units "Command Status", $ help string 0,0xFFFF,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param38 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0010, $ Descriptor 0xC7, $ Data Type 2, $ Data Size in bytes "MB5 Response", $ name "", $ units "Field Value and Channel Indicator", $ help string 0,32767,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places $ Measure block 6 output $ Measure block 6 output Param39 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xCA, $ Data Type 4, $ Data Size in bytes "MB6 Command Value", $ name "", $ units "Floating point value - optionally used with command", $ help string -3000000000.0,3000000000.0,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param40 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xD2, $ Data Type 2, $ Data Size in bytes "MB6 Channel Mask", $ name "", $ units "Channel Mask (0 always for single devices)", $ help string 0,0xFFFF,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param41 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC7, $ Data Type 2, $ Data Size in bytes "MB6 Command", $ name "", $ units "Command and Channel Indicator", $ help string 0,32767,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places $ Measureing block 6 input $ Measureing block 6 input Param42 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0010, $ Descriptor 0xCA, $ Data Type 4, $ Data Size in bytes "MB6 Measuring Value", $ name "", $ units "Requested floating point value (32-bit)", $ help string -3000000000.0,3000000000.0,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param43 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0010, $ Descriptor 0xD2, $ Data Type 2, $ Data Size in bytes "MB6 Device Status", $ name "", $ units "Command Status", $ help string 0,0xFFFF,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param44 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0010, $ Descriptor 0xC7, $ Data Type 2, $ Data Size in bytes "MB6 Response", $ name "", $ units "Field Value and Channel Indicator", $ help string 0,32767,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places $ Measure block 7 output $ Measure block 7 output Param45 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xCA, $ Data Type 4, $ Data Size in bytes "MB7 Command Value", $ name "", $ units "Floating point value - optionally used with command", $ help string -3000000000.0,3000000000.0,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param46 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xD2, $ Data Type 2, $ Data Size in bytes "MB7 Channel Mask", $ name "", $ units "Channel Mask (0 always for single devices)", $ help string 0,0xFFFF,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param47 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC7, $ Data Type 2, $ Data Size in bytes "MB7 Command", $ name "", $ units "Command and Channel Indicator", $ help string 0,32767,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places $ Measureing block 3 input $ Measureing block 7 input Param48 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0010, $ Descriptor 0xCA, $ Data Type 4, $ Data Size in bytes "MB7 Measuring Value", $ name "", $ units "Requested floating point value (32-bit)", $ help string -3000000000.0,3000000000.0,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param49 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0010, $ Descriptor 0xD2, $ Data Type 2, $ Data Size in bytes "MB7 Device Status", $ name "", $ units "Command Status", $ help string 0,0xFFFF,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param50 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0010, $ Descriptor 0xC7, $ Data Type 2, $ Data Size in bytes "MB7 Response", $ name "", $ units "Field Value and Channel Indicator", $ help string 0,32767,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param60 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC8, $ Data Type 4, $ Data Size in bytes "RPI Range", $ name "micro second", $ units "supported RPI range", $ help string 1000,100000,10000, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param69 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC7, $ Data Type 2, $ Data Size in bytes "Assembly 8 Block Size",$ name "", $ units "", $ help string 64,64,64, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param70 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC7, $ Data Type 2, $ Data Size in bytes "Assembly 2 Block Size",$ name "", $ units "Assembly Block Size for 2 Block Format", $ help string 16,16,16, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param73 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type 1, $ Data Size in bytes "Assembly Instance Output 8 Block", $ name "", $ units "", $ help string 100,100,100, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param74 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type 1, $ Data Size in bytes "Assembly Instance Input 8 Block", $ name "", $ units "", $ help string 105,105,105, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param75 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type 1, $ Data Size in bytes "Assembly Instance Output 2 Block", $ name "", $ units "", $ help string 100,100,100, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param76 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC6, $ Data Type 1, $ Data Size in bytes "Assembly Instance Input 2 Block", $ name "", $ units "", $ help string 101,101,101, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places [Groups] Group1 = "Measuring Block 1", $ Group Name 6, $ Number of Members 1,2,3,8,9,10; $ Parameters and Variants in Group Group2 = "Status Block 1", $ Group Name 8, $ Number of Members 4,5,6,7,11,12,13,14; $ Parameters and Variants in Group Group3 = "Measuring Block 2", 6, 15,16,17,18,19,20; Group4 = "Measuring Block 3", 6, 21,22,23,24,25,26; Group5 = "Measuring Block 4", 6, 27,28,29,30,31,32; Group6 = "Measuring Block 5", 6, 33,34,35,36,37,38; Group7 = "Measuring Block 6", 6, 39,40,41,42,43,44; Group8 = "Measuring Block 7", 6, 45,46,47,48,49,50; [Assembly] Assem100 = $ Includes Measuring Block (Floating Point) and Status Block "Output 2 Block Format",$ Name "20 04 24 64 30 03", $ Path , $ Size of the Data Block (in bytes) 0x0000, $ Descriptor ,, $ Reserved, Reserved 32,Param1, $ Member Size, Member Name 16,Param2, 16,Param3, 16,Param4, 16,Param5, 16,Param6, 16,Param7; Assem101 = $ Includes Measuring and Status Data "Input 2 Block Format ", "20 04 24 65 30 03", , 0x0000, ,, 32,Param8, 16,Param9, 16,Param10, 16,Param11, 16,Param12, 16,Param13, 16,Param14; Assem104 = $ Includes Measuring Block (Floating Point) and Status Block "Output 8 Block Format",$ Name "20 04 24 64 30 03", $ Path , $ Size of the Data Block (in bytes) 0x0000, $ Descriptor ,, $ Reserved, Reserved 32,Param1, $ Member Size, Member Name 16,Param2, 16,Param3, 16,Param4, 16,Param5, 16,Param6, 16,Param7, 32,Param15, 16,Param16, 16,Param17, 32,Param21, 16,Param22, 16,Param23, 32,Param27, 16,Param28, 16,Param29, 32,Param33, 16,Param34, 16,Param35, 32,Param39, 16,Param40, 16,Param41, 32,Param45, 16,Param46, 16,Param47; Assem105 = $ Includes Measuring and Status Data "Input 8 Block Format ", "20 04 24 65 30 03", , 0x0000, ,, 32,Param8, $ Measuring block input 16,Param9, 16,Param10, 16,Param11, $ Status block input 16,Param12, 16,Param13, 16,Param14, 32,Param18, $ MB2 input 16,Param19, 16,Param20, 32,Param24, $ MB3 input 16,Param25, 16,Param26, 32,Param30, $ MB4 input 16,Param31, 16,Param32, 32,Param36, $ MB5 input 16,Param37, 16,Param38, 32,Param42, $ MB6 input 16,Param43, 16,Param44, 32,Param48, $ MB7 input 16,Param49, 16,Param50; [Connection Manager] Object_Name = "Connection Manager Object"; Object_Class_Code = 0x06; Connection1 = 0x04010002, $ 0-15 = supported transport classes $ 16 = trigger: cyclic $ 17 = trigger: change of state $ 18 = trigger: application $ 19-23 = trigger: reserved $ 24 = application type: listen-only $ 25 = application type: input-only $ 26 = application type: exclusive-owner $ 27 = application type: redundant-owner $ 28-30 = reserved $ 31 = Direction: Client = 0 / Server = 1 0x44640405, $ 0 = O->T fixed size supported $ 1 = O->T variable size supported $ 2 = T->O fixed size supported $ 3 = T->O variable size supported $ 4-5 = O->T number of bytes per slot (obsolete) $ 6-7 = T->O number of bytes per slot (obsolete) $ 8-10 = O->T Real time transfer format $ 11 = reserved $ 12-14 = T->O Real time transfer format $ 15 = reserved $ 16 = O->T connection type: NULL $ 17 = O->T connection type: MULTICAST $ 18 = O->T connection type: POINT2POINT $ 19 = O->T connection type: reserved $ 20 = T->O connection type: NULL $ 21 = T->O connection type: MULTICAST $ 22 = T->O connection type: POINT2POINT $ 23 = T->O connection type: reserved $ 24 = O->T priority: LOW $ 25 = O->T priority: HIGH $ 26 = O->T priority: SCHEDULED $ 27 = O->T priority: reserved $ 28 = T->O priority: LOW $ 29 = T->O priority: HIGH $ 30 = T->O priority: SCHEDULED $ 31 = T->O priority: reserved ,Param70,Assem100, $ O->T RPI, size, format ,Param70,Assem101, $ T->O RPI, size, format ,, $ proxy config size, format ,, $ target config size, format "I/O 2 Block Format", $ Connection Name "", $ help string "20 04 24 01 2C [Param75] 2C [Param76]"; $ Path Connection2 = 0x04010002, $ 0-15 = supported transport classes $ 16 = trigger: cyclic $ 17 = trigger: change of state $ 18 = trigger: application $ 19-23 = trigger: reserved $ 24 = application type: listen-only $ 25 = application type: input-only $ 26 = application type: exclusive-owner $ 27 = application type: redundant-owner $ 28-30 = reserved $ 31 = Direction: Client = 0 / Server = 1 0x44640405, $ 0 = O->T fixed size supported $ 1 = O->T variable size supported $ 2 = T->O fixed size supported $ 3 = T->O variable size supported $ 4-5 = O->T number of bytes per slot (obsolete) $ 6-7 = T->O number of bytes per slot (obsolete) $ 8-10 = O->T Real time transfer format $ 11 = reserved $ 12-14 = T->O Real time transfer format $ 15 = reserved $ 16 = O->T connection type: NULL $ 17 = O->T connection type: MULTICAST $ 18 = O->T connection type: POINT2POINT $ 19 = O->T connection type: reserved $ 20 = T->O connection type: NULL $ 21 = T->O connection type: MULTICAST $ 22 = T->O connection type: POINT2POINT $ 23 = T->O connection type: reserved $ 24 = O->T priority: LOW $ 25 = O->T priority: HIGH $ 26 = O->T priority: SCHEDULED $ 27 = O->T priority: reserved $ 28 = T->O priority: LOW $ 29 = T->O priority: HIGH $ 30 = T->O priority: SCHEDULED $ 31 = T->O priority: reserved ,Param69,Assem104, $ O->T RPI, size, format ,Param69,Assem105, $ T->O RPI, size, format ,, $ proxy config size, format ,, $ target config size, format "I/O 8 Block Format", $ Connection Name "", $ help string "20 04 24 01 2C [Param73] 2C [Param74]"; $ Path [Port] Object_Name = "Port Object"; Object_Class_Code = 0xF4; Port1 = TCP, "EtherNet/IP port", "20 F5 24 01", 2, $ Routing Capabilities. 0x00, ; [Capacity] ConnOverhead = .004; $ Connection Overhead MaxIOConnections = 1; $ Maximum number of Class 1 Connections MaxMsgConnections = 6; $ Maximum number of Class 3 Connections TSpec1 = TxRx, 10, 2000; $ packets per sec @ 10 bytes TSpec2 = TxRx, 504, 1500; $ packets per sec @ 504 bytes [DLR Class] Revision = 3; Object_Name = "Device Level Ring Object"; Object_Class_Code = 0x47; MaxInst = 1; Number_Of_Static_Instances = 1; Max_Number_Of_Dynamic_Instances = 0; [TCP/IP Interface Class] Revision = 4; Object_Name = "TCP/IP Interface Object"; Object_Class_Code = 0xF5; MaxInst = 1; Number_Of_Static_Instances = 1; Max_Number_Of_Dynamic_Instances = 0; [Ethernet Link Class] Revision = 4; Object_Name = "Ethernet Link Object"; Object_Class_Code = 0xF6; MaxInst = 2; Number_Of_Static_Instances = 2; Max_Number_Of_Dynamic_Instances = 0; InterfaceLabel1 = "Port 1"; InterfaceLabel2 = "Port 2"; $ **************************************************************************** $ EOF $ ****************************************************************************