![]() |
Learn how to easily perform the different measurement methods of UV/VIS Excellence Spectrophotometers from METTLER TOLEDO, such as:
- Color measurement
- Fixed wavelength measurements
- Quantification
- Water Testing
- Scanning
- Bio Applications
Learn also how to download and install more than 80 ready-to-use methods from our
How to Perform Color Measurements with UV/VIS Excellence Spectrophotometers
In this video, you will learn how to determine the color of a sample with our UV/VIS Excellence spectrophotometers.
We will demonstrate this analysis with the color determination of an electrolyte. As decomposition progresses, the color of the electrolyte turns yellowish. Therefore, we will measure the yellowness index of the electrolyte. This parameter can be used for quality control purposes, as the degree of decomposition reflects the water content within the sample.
Welcome from our Mettler Toledo application lab in Switzerland. In this video I will show you how to determine the color of a sample with our UV-Vis Excellence spectrophotometers. I will demonstrate this analysis with a color determination of a battery electrolyte. As decomposition progresses, the color of the electrolyte turns yellowish. Therefore we will measure the yellowness index of the electrolyte. This parameter can be used for quality control purposes as the degree of decomposition reflects the water content within the sample. Let's start with method configuration. To create a new method, click Methods and select Scanning. All predefined color calculations are located in Scanning, even if no full spectrum is required for the color calculation. By clicking New, the method configuration is started. To unlock color calculations, you have to activate color. For scan based color scales, you can select between various illuminance and observers. Most of the time, however, illuminant C and observer 2 degree are used and do not need to be changed. By confirming the input, The method editor is shown with predefined method functions. Under spectrum evaluation, you can select the unit of the measured spectrum and some further post-processing options like smoothing and peak finding. As the y-axis is based on the transmittance spectrum, we change the unit to percent T. To calculate the color number. You have to add the method function calculation by clicking insert. The calculation can only be added after spectrum evaluation. Now we can define the name. Yellowness index. As a unit for the Uranus index, we can define Y_I. Where can you find the correct formula? By clicking on Formula, you get input a formula. Color calculations are predefined. You should navigate to the number keyboard on the top right and click C for color. Here you can find the list of all predefined color calculations. All the calculations are defined for a path lengths of 10 mm. You can select the desired color scale from this list, in this case yellowness index. The correct formula is automatically inserted. Additionally, you can define the number of decimals, for example two. Some color calculations are also predefined under result proposals. In this case the method function is automatically filled. The operator can define an upper and lower limit for the result for quality control. It is important to mention that you can add as many calculations as you want. So with only one method you can determine for example several color scales. Or get other information, like absorbance at a specific wavelength. You simply insert another calculation method function for this purpose. Last, you can define how the results should be displayed on the screen. As we have only defined one result, we define one result field and select our one yellow index from the results list. Now you can save the method and are ready to start the method by clicking start. You now have the possibility to save the method to your home screen with add to home. This will create a shortcut on the home screen and is highly recommended for frequently used methods as they can be started with one click. For this you have to define a name, for example Y-I ELECTROLYTE By saving it, you will end up on the home screen. Just click the shortcut to return to the same screen as before. Now you can define the sample ID and change the dilution and correction factor if needed. Clicking Start a second time will guide you through the workflow. First, we have to insert the blank cuvette. By clicking OK, the blank determination starts. Afterwards, we are asked to insert the sample cuvette. Again, the measurement is started by clicking OK. Measured transmission spectrum is shown on the screen. With the button calculated results you can switch between the spectrum and the calculated results, which is in this case the yellowness index of your sample. I hope this short video was helpful understanding how to set up a color measurement with our UV with excellent spectrophotometers. This analysis can also be automated with our cuvette changer for up to eight samples or for up to 303 samples with our in -motion auto sampler. Check out our automation webinar or our automation guide here. Thank you for watching this video. And don't miss our other videos explaining more measurement categories and how to get predefined methods from our application library on empty dot com.
How to Perform Fixed Wavelength Measurements with UV/VIS Excellence Spectrophotometers
In this video, you will learn how to set up a method for measuring the absorbance at several wavelengths and how to calculate multiple results.
For example, we have chosen the analysis of olive oil samples from our application library.
How to Perform Quantification with UV/VIS Excellence Spectrophotometers
In this video, you will learn how to set up a quantification method with your own calibration curve to quantify an analyte according to the Beer-Lambert law.
The analysis is demonstrated with the quantification of Per- and Polyfluoroalkyl substances, called PFAS for short.
Welcome from our Metal Toledo application lab in Switzerland. In this video I will demonstrate you how to measure full spectrum with our array spectrophotometers. The full spectrum is very useful to identify the wavelength of the peak maxima to record a calibration curve. For this purpose we will measure one standard of a pair and polyfluoroalkyl substances. Abbreviated with PFAS. How to set up the calibration curve will then be shown in the next dedicated video. Let's start with the method configuration. To create a new method click Methods and select Scanning. By clicking New the method configuration is started. If we want to measure multiple samples, we can activate multiple determination and define whether we want to measure a closed or open sample series. Now we can see the method editor. The analysis tools, such as peak finding or smoothing, can be found under Spectrum Evaluation. Here we can select the unit of the spectrum: absorbance or transmittance. With smoothing, different degrees can be selected: low, medium or high. You can select whether peaks, valleys or both should be identified. As we are measuring an absorbance spectrum, figuring out where the peak maximum is, we can select peaks. Valleys are more interesting for transmission spectra. The sensitivity of the algorithm can be tuned. You can select between low and high or user defined. Last, you can define in which region of the spectrum the algorithm should be applied. The literature already gave us a hint that the expected maximum is between 500 and 800 nanometers. Now you can see the results. We can save the method and we are ready to start the method by clicking start. Now we can define the sample ID or click on add to home. This will create a shortcut on the home screen and is highly recommended for frequently used methods as they can be started with one click. This is explained in detail in our how to measure color video. Click Start again and you are guided through the workflow. First, you have to insert the blank cuvette. By clicking OK, the blank determination starts. Afterwards, we are asked to insert the sample. By confirming this pop-up the measurement starts again. The full spectrum is shown on the screen and the detected peaks in the region of interest are labeled. By clicking one peak table, a list of all found peaks is shown. You can also zoom into the spectrum with two fingers and return to the default view by a double click on the spectrum. The found peak maximum can be used for example in a next quant method to record a calibration curve to quantify PFAS. I hope this short video was helpful understanding how to set up a scan method with various additional settings. The workflow is always the same, independent from your application. Thank you for watching this video and don't miss our other videos explaining more measurement categories and how to get predefined methods from our application library on mti.com.
How to Perform Scan Measurements with UV/VIS Excellence Spectrophotometers
In this video, you will learn how to measure a full spectrum with our array spectrophotometers.
A full spectrum is very useful to identify the wavelength of a peak maximum to record a calibration curve. For this purpose, we will measure one standard solution of Per- and Polyfluoroalkyl substances, abbreviated PFAS.
How to Perform Color Testing According to Pharmacopeia with UV/VIS Excellence Spectrophotometers
In this video, we will demonstrate how you can easily and correctly determine color according to pharmacopeia with METTLER TOLEDO’s UV7 Excellence spectrophotometers and LabX™ UV/VIS software.
In our Pharma Color Guide, we explain the theory of color determination in more detail.
Mm-hmm. Welcome from our Mettler Toledo application lab here in Switzerland. In this video I will demonstrate you how you can easily and correctly determine color according to pharmacopeia with Mettler Toledo's UV7 excellent spectrophotometers and the LabX UV-VIS software. As today's example I will guide you through a step-by-step tutorial on color determination according to the European Pharmacopeia. In our Pharma Color Guide I'm explaining the theory of color determination in more detail. By downloading the guide you will also receive the ready-to-use LabX methods for measuring color according to both Pharmacopeia. You can download the guide here. So let's go to the lab bench now setting up our instrument. First we need to import the methods into the LabX UV-VIS software. For this, we select Import LabX Method and mark the methods of interest from our target folder. After the successful import, the selected methods are shown here in the analysis tab. As the European Pharmacopeia color scale is based on the comparison of measured CIE Lab values with CIE Lab values from color standards, we first need to import all reference values into the LabX database. To do so, we need to execute the corresponding Caleb table method. In this example I will only compare against the standard brown P_ We select the method EOP Caleb table B_ and start the task on the connected UV7 spectrophotometer. In the task editor, we upload the task parameter file for brown color. The task parameter file is part of the method package and contains the reference values for all brown car standards. By clicking OK, the method starts on the instrument and the reference values are stored in the Levix database. These initial steps need to be done only once. The values will now remain in the database. Now the setup is done and we are ready to measure samples according to the European Pharmacopeia. To start the sample analysis we start the method UP 00B and define the sample list. After confirming, the method starts on the instrument. First we need to measure the blank. I'm using distilled water for that. After determining the blank, the operator is asked to insert the first sample. As soon as the measurement is done, the color standard closest to the sample value is shown as a result. I hope this short video helped you understand how to determine color according to the European Pharmacopoeia. The workflow for the US Pharmacopoeia is very similar and our Pharma Color Guide provides a detailed description along with some background theory. Thank you for watching this video and don't miss our other videos explaining the various measurement categories and how to download more ready-to-use methods from our application library on mt.com.
How to Perform Bio Applications with UV/VIS Excellence Spectrophotometers
In this video, we will demonstrate how you can perform bio applications as DNA analysis and proten measurements with METTLER TOLEDO’s UV5Nano and UV5Bio Excellence spectrophotometers.
In our Life Science Toolbox you will find helpful theory and and best practices to improve your results.
Method Retrieval and Installation
How to Receive and Install Methods on UV/VIS Excellence Spectrophotometers
Did you know that there are more than 80 ready-to-use application methods available for UV/VIS Excellence spectrophotometers? In this video, you will learn where to find the application packages and how to download them from mt.com as well as how to install a new method on your instrument.
Welcome from our Metla Toledo application lab in Switzerland. Did you know that there are more than 80 ready-to-use application methods available for UV-Vis Excellence spectrophotometers? In this video, I will show you where to find the application packages and how to download them from mt.com as well as how to install a new method on your instrument. This is our homepage mt.com. Let's navigate together the application library. Click Product and Solutions, hover to Analytical Instruments and click Applications. Here you will find an overview of the various application libraries for all our analytical instruments. As we are looking for a new UV-Vis application, we can scroll down and select UV-Vis Applications. In the UV-Vis application library you can find all available application packages for Mettler Toledo UV-Vis spectrophotometers. Let's select for example the determination of vitamin A. Here you can already see a little description of the application and a preview of the application note. To download the application package, you have to enter your email address and confirm the terms of use and privacy statement. By clicking continue you're asked to enter some more details and click download to proceed. After your account on empty.com is activated, you can click on personal library. Here you can download now the application note as PDF. the standalone method as X_M_L_ file or the LabX method as L_M_T_ file. We are now interested in the standalone method so we can download this file. Depending on your browser settings, you have to right-click on the method and select save link and select the directory for the download, for example directly on a USB flash drive. Now you can insert the USB flash drive in the USB port of the UV5 spectrophotometer, for example right side of the terminal. The instrument will notify you that a USB flash drive was recognized. After you have confirmed the pop-up, you can click on Setup, select Maintenance and Service and Import and Export. After you have selected Import, you can choose the method from your connected USB flash drive. As there is only one method stored, you can select the method and click Start. After the successful import, you can go back to the home screen and select Methods and in this case for Vitamin A, select Fixed Wavelength. And here is your imported method. Ready to use. Thank you for watching this video. I hope it was helpful to understand how to download methods from our application library on empty.com. The application library is continuously being expanded and it's worthy checking back regularly. For individual method support we recommend getting in touch with your local Mettler Toledo sales representative. Don't miss our other videos explaining the available measurement categories on METTLER TOLEDO Excellence Spectrophotometers. See you there.










