Several options in the Mettler Toledo STA software provide easy-to-use quality control possibilities, that allow you to compare results to known reference curves, determine whether characteristic material properties lie within predefined limits, and electronically transfer and store data. In this video, you will learn how to Compare measurements with known, good quality reference materials. Create a table template for statistics. Add evaluations to the statistics table for straightforward result comparisons. We will also show you how to set up automatic evaluations to help you save time on your routine analysis. The first part of this tutorial describes the reference curve feature, which allows the user to select a previously measured curve of a known, good quality product from a database and use this as a reference curve against which to compare new product batches. Create a method in the method window. Reference Curve under the Miscellaneous tab and click on the Reference Curve icon. A dialog box will appear. Check the Display box and click on Select to choose a reference substance from the database. Finally, choose the upper and lower tolerances. And click OK. The quality control software option shows the upper and lower limits allowed for the analysis, together with the measurement curve displayed between these limits. With the help of this software feature, the quality tester can immediately see if the tested product is within the specified tolerances. Another feature of the quality control software option is that quality checks of different batches, production lots, Types of materials, etc, can be statistically evaluated. I will now go on to demonstrate the step wise process of creating a table of statistics, using three batches of polyethylene terephthalate (pet) as an example. This involves two steps: designing the table template, including evaluations. Once correctly set up, the current measurement and its results are automatically transferred to the statistics table. Start off by creating a template to define which results are to be included in the table. Open the evaluation of polyethylene terephthalate in the evaluation window. Select the "Statistics" tab, followed by "New" under "Template." The "Statistics Template" dialog box appears. To include results in the template, simply select the result of the interest. Selections are shown in magenta. Right-click and select Add results to Statistics Template from the drop-down menu. In this example, we have determined the glass transition and melting temperatures on the second heating run of PET to eliminate any effects caused by thermal history. Left and right evaluation limits are also displayed. which must be expanded to include future measurements with different temperature ranges. Following examination of the p e t evaluation, useful limits for the p e t sample exist in the glass transition range of thirty to one hundred and forty degree celsius and a melting enthalpy range of one hundred to three hundred degree celsius. Repeat these steps if you wish to include additional results. To save the template, click Save As. Enter a template name and click OK. Finally, create your table by once again selecting New, but this time under File. Open the template you just created and click Include to transfer the results from the Open p.e.t. evaluation. This can be done for more than one evaluation. For example: p e t, batch one, two, and three. The results that fit into the ranges defined in the template are included and displayed in the upper table. The evaluation column displays the name and date of an evaluation ; the date column is the time the evaluation was added to the table. Results are displayed in the remainder columns. As defined in the template, the following statistics are automatically calculated in the lower table: Mean value, mean value of the evaluation results, standard deviation, standard deviation of the evaluation results, minimum, minimum result value, maximum, maximum result value. Number of Data Samples To save the statistics, click Save As, enter your preferred name, and click OK. You can even export a statistics evaluation in CSV (Excel format) character separated values. Check the Include Results box to include statistics in the export file. Often, quality control laboratories routinely perform the same measurements again and again. Any step in the quality control process that can be automated will therefore be helpful to save time and money. The Starry software allows users to set up an automatic evaluation, including a result assessment. For more information on automatic evaluation, visit www.mt .com. Forward slash t a dash videos. With the help of the quality control option in Star e software, quality checks of different batches, production lots, types of materials etc. can be graphically compared and statistically evaluated to ensure they lie within predefined quality limits. For more t a related how to videos please go to www .m t.com. Forward slash t a dash videos.
In this tutorial you will learn how to program and apply the Quality Control software option for reliable and easy product assessment.
The QC option offers the following benefits:
- Online reference curve comparisons – detect wrong measurements early on.
- Determination of material quality – characteristic material properties must lie within predefined limits.
- Robust data integrity – electronic transfer and storage of measurement results.
STARe is the most complete and comprehensive thermal analysis software on the market and provides unrivalled flexibility and unlimited evaluation possibilities.
For more information on thermal analysis software or to download and test the free evaluation software
For more TA tips and hints
Latest thermal analysis news




