Multichannel Pipettes | Rainin Multichannel Pipette | Pipet Lite XLS ◄
Multichannel Pipette Pipet-Lite XLS

Multichannel Pipette Pipet-Lite XLS

Precision and manual control across all channels

 

What is a multichannel pipette?

Multichannel pipettes are air-displacement pipettes that work similarly to single-channel pipettes. Multichannel pipettes feature multiple nozzl...

Multichannel pipettes are air-displacement pipettes that work similarly to single-channel pipettes. Multichannel pipettes feature multiple nozzles (usually 8 or 12) arranged in a horizontal row on which tips are mounted. Channels are spaced 9mm apart to align with the wells of a 96-well plate – the most common assay platform in life science labs to speed up routine pipetting.


 
Manual Multichannel Pipette Pipet-Lite XLS+
Manual Multichannel Pipette Pipet-Lite XLS+
Pipet-Lite XLS+ Manual Multichannel Pipette
Multichannel Pipette Pipet-Lite XLS

Pipette models and tech specs

 
Filter:
Set filter
Clear All
 
Volume Range
Increment (manual)
Volume
Accuracy ± (%) (µl)
Precision ± (%) (µl)
Material No.: 17013807
Volume Range 0.5 µL – 10 µL ;
Increment (manual) 0.02 µL ;
Volume 1 µL ;5 µL ;10 µL ;
Accuracy ± (%) (µl)4 % / 0.04 µL ; 1.5 % / 0.075 µL ; 1 % / 0.1 µL ;
Precision ± (%) (µl)5 % / 0.05 µL ; 1.5 % / 0.075 µL ; 0.5 % / 0.05 µL ;
Tip TechnologyLiteTouch System LTS ;
Channels12 ;
Maximum Volume
Material No.: 17013810
Volume Range 20 µL – 200 µL ;
Increment (manual) 0.2 µL ;
Volume 20 µL ;100 µL ;200 µL ;
Accuracy ± (%) (µl)2.5 % / 0.5 µL ; 0.8 % / 0.8 µL ; 0.8 % / 1.6 µL ;
Precision ± (%) (µl)1.2 % / 0.24 µL ; 0.25 % / 0.25 µL ; 0.3 % / 0.6 µL ;
Tip TechnologyLiteTouch System LTS ;
Channels12 ;
Maximum Volume
Material No.: 17013808
Volume Range 2 µL – 20 µL ;
Increment (manual) 0.02 µL ;
Volume 2 µL ;10 µL ;20 µL ;
Accuracy ± (%) (µl)7.5 % / 0.15 µL ; 1.5 % / 0.15 µL ; 1 % / 0.2 µL ;
Precision ± (%) (µl)4 % / 0.08 µL ; 1.5 % / 0.15 µL ; 0.5 % / 0.1 µL ;
Tip TechnologyLiteTouch System LTS ;
Channels12 ;
Maximum Volume
Material No.: 17013811
Volume Range 20 µL – 300 µL ;
Increment (manual) 0.5 µL ;
Volume 30 µL ;150 µL ;300 µL ;
Accuracy ± (%) (µl)2.5 % / 0.75 µL ; 0.8 % / 1.2 µL ; 0.8 % / 2.4 µL ;
Precision ± (%) (µl)1.5 % / 0.45 µL ; 0.3 % / 0.45 µL ; 0.25 % / 0.75 µL ;
Tip TechnologyLiteTouch System LTS ;
Channels12 ;
Maximum Volume
Material No.: 17013809
Volume Range 5 µL – 50 µL ;
Increment (manual) 0.05 µL ;
Volume 5 µL ;25 µL ;50 µL ;
Accuracy ± (%) (µl)3.5 % / 0.18 µL ; 1.2 % / 0.3 µL ; 0.8 % / 0.4 µL ;
Precision ± (%) (µl)2 % / 0.075 µL ; 0.5 % / 0.125 µL ; 0.4 % / 0.2 µL ;
Tip TechnologyLiteTouch System LTS ;
Channels12 ;
Maximum Volume
Material No.: 17013802
Volume Range 0.5 µL – 10 µL ;
Increment (manual) 0.02 µL ;
Volume 1 µL ;5 µL ;10 µL ;
Accuracy ± (%) (µl)4 % / 0.04 µL ; 1.5 % / 0.075 µL ; 1 % / 0.1 µL ;
Precision ± (%) (µl)5 % / 0.05 µL ; 1.5 % / 0.075 µL ; 0.5 % / 0.05 µL ;
Tip TechnologyLiteTouch System LTS ;
Channels8 ;
Maximum Volume
Material No.: 17013805
Volume Range 20 µL – 200 µL ;
Increment (manual) 0.2 µL ;
Volume 20 µL ;100 µL ;200 µL ;
Accuracy ± (%) (µl)2.5 % / 0.5 µL ; 0.8 % / 0.8 µL ; 0.8 % / 1.6 µL ;
Precision ± (%) (µl)1.2 % / 0.24 µL ; 0.25 % / 0.25 µL ; 0.3 % / 0.6 µL ;
Tip TechnologyLiteTouch System LTS ;
Channels8 ;
Maximum Volume
Material No.: 17013803
Volume Range 2 µL – 20 µL ;
Increment (manual) 0.02 µL ;
Volume 2 µL ;10 µL ;20 µL ;
Accuracy ± (%) (µl)7.5 % / 0.15 µL ; 1.5 % / 0.15 µL ; 1 % / 0.2 µL ;
Precision ± (%) (µl)4 % / 0.08 µL ; 1.5 % / 0.15 µL ; 0.5 % / 0.1 µL ;
Tip TechnologyLiteTouch System LTS ;
Channels8 ;
Maximum Volume
Material No.: 17013806
Volume Range 20 µL – 300 µL ;
Increment (manual) 0.5 µL ;
Volume 30 µL ;150 µL ;300 µL ;
Accuracy ± (%) (µl)2.5 % / 0.75 µL ; 0.8 % / 1.2 µL ; 0.8 % / 2.4 µL ;
Precision ± (%) (µl)1.5 % / 0.45 µL ; 0.3 % / 0.45 µL ; 0.25 % / 0.75 µL ;
Tip TechnologyLiteTouch System LTS ;
Channels8 ;
Maximum Volume
Material No.: 17013804
Volume Range 5 µL – 50 µL ;
Increment (manual) 0.05 µL ;
Volume 5 µL ;25 µL ;50 µL ;
Accuracy ± (%) (µl)3.5 % / 0.18 µL ; 1.2 % / 0.3 µL ; 0.8 % / 0.4 µL ;
Precision ± (%) (µl)2 % / 0.075 µL ; 0.5 % / 0.125 µL ; 0.4 % / 0.2 µL ;
Tip TechnologyLiteTouch System LTS ;
Channels8 ;
Maximum Volume
Material No.: 17014497
Volume Range 100 µL – 1,200 µL ;
Increment (manual) 2 µL ;
Volume 100 µL ;600 µL ;1,200 µL ;
Accuracy ± (%) (µl)3.6 % / 3.6 µL ; 0.8 % / 4.8 µL ; 0.8 % / 9.6 µL ;
Precision ± (%) (µl)1 % / 1 µL ; 0.3 % / 1.8 µL ; 2.4 % / 2.4 µL ;
Tip TechnologyLiteTouch System LTS ;
Channels12 ;
Maximum Volume 1,200 µL ;
Material No.: 17014496
Volume Range 100 µL – 1,200 µL ;
Increment (manual) 2 µL ;
Volume 100 µL ;600 µL ;1,200 µL ;
Accuracy ± (%) (µl)3.6 % / 3.6 µL ; 0.8 % / 4.8 µL ; 0.8 % / 9.6 µL ;
Precision ± (%) (µl)1 % / 1 µL ; 0.3 % / 1.8 µL ; 2.4 % / 2.4 µL ;
Tip TechnologyLiteTouch System LTS ;
Channels8 ;
Maximum Volume 1,200 µL ;
Comparison

Documentation

Manuals

Pipet-Lite XLS+ Manual Pipettes Operating Instructions
Operating instructions for the Rainin Pipet-Lite XLS+ single-channel, multichannel. and adjustable spacer manual pipettes.

Brochures

XLS+ Multichannels Brochure
This document provides an overview of how the XLS+ multichannel pipettes raise the bar on multichannel pipetting and performance.
XLS+ Pipette Family Brochure
An overview of the features and benefits of the XLS+ pipette family, including performance, comfort and control.

Datasheets

Pipet-Lite XLS+ Multichannels Datasheet
This datasheet provides an overview of how the Pipet-Lite XLS+ Multichannel is fast loading, easy on your hand and delivers precise and consistent sam...

Certificates

SmartStand - Declaration of Conformity
SmartStand - Declaration of Conformity

Services

800 METTLER
Call Service

Expert Service – Tailored to Fit Your Pipetting Needs

METTLER TOLEDO supports and services your pipettes through their entire life-cycle, from good pipetting techniques to preventive maintenance and calibration to equipment repair.

Performance
Maintenance & Optimization
Compliance
Calibration & Quality

Video

Thank you for visiting www.mt.com. We have tried to optimize your experience while on the site, but we noticed that you are using an older version of a web browser. We would like to let you know that some features on the site may not be available or may not work as nicely as they would on a newer browser version. If you would like to take full advantage of the site, please update your web browser to help improve your experience while browsing www.mt.com.