Tell us about your balances and compliance needs. We can help you choose.
E1
Reference standards are used to calibrate other weights.
E2
Reference and calibration weights for analytical and microbalances
F1
Precision working class for regulated laboratories
F2
Precision working class for less demanding checks
M1
Industrial and trade, commercial weighing
M2
Industrial and trade, platform scales
M3
Trade and coarse, heavy weighing
M1-2
Special intermediate, 50 kg to 5000 kg, class III instruments
M2-3
Special intermediate, 50 kg to 5000 kg, class III instruments

What is the difference between OIML and ASTM weight classes?

OIML R111 is the global system, with nine classes from E1 to M3, while ANSI/ASTM E617 is the North American system, with designations from 000 to 7. Both systems rank weights by maximum permissible error for each nominal value, but neither standard equates a class in one system with a class in the other. Any cross-mapping is therefore approximate.

What is the tolerance of an OIML E2 or F1 weight at 1 kg?

At 1 kg, the maximum permissible error is 1.6 mg for an OIML E2 weight and 5.0 mg for an F1 weight. The tolerance is an absolute mass fixed for that nominal value, not a percentage. A heavier or lighter weight of the same class has a different limit, which you read directly from the R111 table.

Which weight class do you need for an analytical balance?

For analytical balances with a readability of 0.1 mg, laboratories typically use OIML E2 or F1 weights for calibration and performance testing. The appropriate class depends on the application’s measurement uncertainty and tolerance requirements; no fixed rule applies. E2 weights are generally preferred for tighter tolerances and higher-performance instruments, such as semi-micro balances, while F1 weights are often sufficient for routine analytical weighing tasks.

How often should calibration weights be recalibrated?

The recalibration interval for a weight set depends on how the weights are used, the working environment, and your GMP, GLP, or USP quality system. No fixed interval applies to every set. An accredited ISO/IEC 17025:2017 mass laboratory calibrates the weights and issues the certificate that documents their traceability chain.

What does traceable to the SI kilogram mean?

An unbroken chain of calibrations links your weight to the SI unit of mass. Since 20 May 2019, the kilogram has been defined by the Planck constant instead of a physical artifact. National metrology institutes realize the kilogram using the Kibble balance and the Avogadro, or X-ray crystal density, method, and every accredited calibration below them inherits that reference.

Can legally verified weights be used for balance testing?

Legal verification confirms that a weight meets trade metrology rules, but it is not an accredited ISO/IEC 17025:2017 calibration and does not report the uncertainty required by a quality system. Under GMP, GLP, or the revised USP 41, balance testing calls for a current ISO/IEC 17025:2017 calibration certificate.

Comparadores de Massa
Pesos Padrão para Balanças
Calibração de Pesos Classe E2 OIML
Pesos Padrão Classe F1 OIML
Pesos de Calibração Classe M1 OIML
USP 41 - Revisão 2026

USP 41 - Revisão 2026

Os Capítulos Gerais 41 e 1251 foram revisados pela USP em julho de 2025 e entraram em vigor em 1º de...

Guia de Manuseio Correto de Pesos de Teste: 12 Dicas Práticas

Guia de Manuseio Correto de Pesos de Teste:
12 Dicas Práticas

Este guia contém dicas para o manuseio correto de pesos de teste, que são essenciais para manter a p...

Serviço de Calibração de Balanças

Calibração de Balanças - Serviço

Nossos serviços de calibração garantem desempenho preciso e conformidade com os regulamentos locais...

Eu quero...
Precisa de ajuda?
Nossa equipe está aqui para atingir as suas metas. Fale com nossos especialistas.