In high-pressure thermal power plants, water and steam purity are essential to protect costly components from corrosion and to avoid expensive repairs and potentially catastrophic failures. Sodium is a key parameter for monitoring pure water treatment system performance and for detecting contamination within the thermal cycle. Sodium analyzer. The new METTLER TOLEDO Thornton 2300Na sodium analyzer provides efficient and reliable monitoring of low sodium concentrations for these applications. It uses industry-proven technology, but with innovative approaches that simplify calibration and improve measurement reliability. Let's take a look inside this analyzer, following the sample flow path. The sample enters and fills a constant head chamber that stabilizes the pressure and flow through the rest of the analyzer. The sample then flows through diffusion tubing within the reagent container where it absorbs reagent vapor through the tubing wall. The reagent raises the sample pH to prevent interference and assure low level sensitivity. The pH adjusted sample flows to the sodium and pH electrodes for measurement. The pH electrode confirms that the sample pH has been adequately raised. Finally, the sample overflows to drain. An air pump supplies a steady stream of bubbles to provide mixing around the sodium electrode. The Thornton 2300NA sodium analyzer provides unattended automatic calibration, a valuable time-saving capability. Starting the auto calibration sequence, the valve at the left stops the sample flow. At the same time, the two calibration valves on the right energize to fill the fixed volume of tubing between them with calibration standard solution, with excess solution going to drain. The two calibration valves then de-energize to push the small volume of calibration standard into the electrode chamber where it is diluted for calibration. Additional precise amounts of standard solution are added by repeated energizing of the calibration valves. Measurements are taken after each addition. Sodium analyzer. This video demonstrates how to measure sodium contamination in power plant water cycle chemistry to help prevent corrosion and minimize deposits. In the power plant, long-term efficient generation depends on minimizing corrosion and deposition within the steam/water cycle. As a leader in meeting stringent deionized water quality requirements with other measurements, METTLER TOLEDO Thornton has expanded its portfolio to include sodium measurement, the key parameter for initiating regeneration of cation exchange resin and for assuring water purity. The Thornton 2300Na sodium analyzer offers a new design for a traditional measurement for pure water treatment and power cycle chemistry monitoring. This analyzer provides assurance of water purity to minimize corrosion and maximize water production. Early detection of trace contamination allows time for planning corrective action before condenser leaks enlarge and serious damage occurs. The design of the 2300Na is based on extensive instrumentation experience and is optimized to handle these measurement challenges. The 2300Na uses a particularly simple automatic calibration method and also provides the ability to measure grab samples easily, in addition to measuring pressurized samples from process streams. Its implementation with an operator interface common to other parameters including conductivity, dissolved oxygen, pH, TOC and ORP, makes it especially convenient for installation and operator training. Read more about the on-line sodium analysis in our white paper - Advanced On-line Sodium Measurement: http://www.mt.com/global/en/home/products/Process-Analytics/sodium-silica-analyzer/sensor-sodium-Na.html Features and benefits of the 2300Na: Fully automatic, unattended calibration assures reliable operation while saving time Reagent addition confirmation by pH to secure consistent measurement results Convenient grab sample measurement for additional samples and quality control checks from other areas of the plant Choice of analyzer enclosures for complete protection in the plant or a more accessible version for cleaner locations Unattended automatic calibration for maximum accuracy and operator time savings Sodium analyzer. This video demonstrates how to measure sodium contamination in power plant water cycle chemistry to help prevent corrosion and minimize deposits. In the power plant, long-term efficient generation depends on minimizing corrosion and deposition within the steam/water cycle. As a leader in meeting stringent deionized water quality requirements with other measurements, METTLER TOLEDO Thornton has expanded its portfolio to include sodium measurement, the key parameter for initiating regeneration of cation exchange resin and for assuring water purity. The Thornton 2300Na sodium analyzer offers a new design for a traditional measurement for pure water treatment and power cycle chemistry monitoring. This analyzer provides assurance of water purity to minimize corrosion and maximize water production. Early detection of trace contamination allows time for planning corrective action before condenser leaks enlarge and serious damage occurs. The design of the 2300Na is based on extensive instrumentation experience and is optimized to handle these measurement challenges. The 2300Na uses a particularly simple automatic calibration method and also provides the ability to measure grab samples easily, in addition to measuring pressurized samples from process streams. Its implementation with an operator interface common to other parameters including conductivity, pH, ORP, dissolved oxygen and total organic carbon, makes it especially convenient for installation and operator training. Read more about the on-line sodium analysis in our white paper - Advanced On-line Sodium Measurement: http://www.mt.com/global/en/home/products/Process-Analytics/sodium-silica-analyzer/sensor-sodium-Na.html Features and benefits of the 2300Na: Fully automatic, unattended calibration assures reliable operation while saving time Reagent addition confirmation by pH to secure consistent measurement results Convenient grab sample measurement for samples taken from other locations in the plant To learn more about the 2300Na sodium analyzer, as well as related instrumentation for specific and cation conductivity, pH, ORP, dissolved oxygen and total organic carbon, visit the METTLER TOLEDO Thornton website. Sodium analyzer.
On-line Sodium Analyzer
The on-line sodium analyzer 2300Na offers a new design for a traditional measurement for pure water treatment and power cycle chemistry monitoring. The video explains how the sodium analyzer provides assurance of water purity to minimize corrosion and maximize water production.










