IND131xx Junction-box terminal for hazardous areas - Discontinued Product

Compact scale terminal with enhanced connectivity and integral load cell summing

The IND131xx Junction Box scale terminal features an IND131xx DIN unit and a load cell summing board mounted in a robust stainless steel enclosure. The J-box is available with either conduit hubs or ATEX-certified glands.The enclosure's integrated mounting brackets simplify secure wall-mounting.

Discontinued since: Feb, 2023

Call for Quote

Accessories - IND131xx Junction-box terminal for hazardous areas

Special features and benefits - IND131xx Junction-box terminal for hazardous areas

  • Support for analog scale bases
  • DC (External) power supply
  • Broad connectivity options
    • Serial  - RS-232 (standard) and RS-232/485 with support for Modbus RTU protocol (optional)
    • PLC – Analog Output / A-B RIO™ / Ethernet/IP™ / Modbus® TCP / PROFIBUS® DP / ControlNet™ / DeviceNet™
    • Discrete Inputs/Outputs
      • 2 Inputs /4 Outputs
      • Solid state -- open collector type
  • Optimum target control
    • Single-latched or coincidence target
    • Three coincidence comparators
    • Internal rate calculation assignable to comparators
  • Enhanced performance for process applications
    • Ultra-fast A/D conversion (366 Hz), target comparison (50 Hz) and PLC update (20 Hz) rates
    • Patented TraxDSP™ digital filtering
    • Display resolution 100,000d (max)
  • Enhanced productivity and efficiency
      • SD memory card
      • Backup and restore for setup and calibration
      • Portability of setup to other terminals
    • Calibration choices
      • Scale calibration though PLC
      • Step calibration
      • CalFREE® -Calibration without test weights
      • Traditional
  • Service friendly
    • Modular design assures ease of service and multiple mounting possibilities
    • Diagnostic LEDs and error codes for easy troubleshooting
    • TraxEMT™ performance monitoring and recording for easy operational audit
    • Serial and Discrete I/O tests
  • Weights and Measures Approvals
    • NTEP, Class III/IIIL 10,000d Coc 09-051
    • OIML, Class III 6,000e (R76/2006-NL 1-09.26)
    • MID, OIML R51/R61 
    • Canada Class III/IIIHD n max. 10000/20000
  • Hazardous Area Approvals

    • USA - FM: NI / I, II, III / 2 / ABCDEFG /, T5 Ta = 40°C, I / 2 / IIC / T5 Ta = 40°

    • Canada - FM:  NI / I / 2 / ABCD / T5 Ta, = 40°C, DIP / II, III / 2 / EFG / T5 Ta = 40°C

    • ATEX: II 3 G Ex nA nL [nL] IIC T5, II 3 D Ex tD A22 IP 65 T, 100°C

    • IECEx: Ex nA nL [nL] IIC T5, Ex tD A22 IP65 T100°C

    • NEPSI: Pending

Specifications- IND131xx Junction-box terminal for hazardous areas