The CFR option in thermal analysis STARe software provides the mandatory technical controls for compliance with 21 CFR Part 11 regulations on access control, user rights, electronic records, electronic signatures and audit trails.
Part 1: Access Control
To guarantee that all work in a thermal analysis computerized system is attributed to a single individual, each user must have a unique user identity for logging on. Part 1 of the video series covers this topic of how to best use the STARe 21 CFR 11 software option for data integrity in thermal analysis.
This video shows you how to create unique user accounts that are password protected. Additionally, passwords and user policies can be defined according to the security requirements of your organizations.
The c f r option provides the mandatory technical controls for compliance with twenty one c f r part eleven regulations on: access control, user level management, electronic records, electronic signatures and audit trail. Star e enables access control to the application, user level management, electronic signatures and audit trails. Access control is part one of a series of four how-to videos, teaching you how to make best use of the STAR -E CFR option for data integrity. To guarantee that all work in a thermal analysis computerized system is attributed to a single individual, each user must have a unique user identity for logging on. In this video, we show you how to create unique user accounts that are password protected. Any user with administrator rights can set up and configure user accounts in Star eSoftware. Start by logging into the software and click on Install Window. Then select Home User Accounts from the main menu bar. On the User Accounts page, add the first names, last names, An email address of a new user to the relevant fields. The notifications option allows you to configure email alerts coming directly from Star eSoftware. The procedure is explained in a separate how -to video titled How to Configure Email Alerts in Star eSoftware. Users can be assigned a specific role with an appropriate signature level if the User Rights software option is activated. These aspects are covered in Part two of this video series. To enable single sign ons, enter the user name of an existing Windows user in the Windows User field. Accounts cannot be deleted, but it's possible to disable them by selecting Disable user account. The Change Password next time user logs on default setting automatically prompts users to set their passwords the first time they log on to the system. Add any optional information to the Remarks field and click File>Save. Save. In the Save as dialog box, enter the user name. Make sure it does not contain any at (@) characters. You have now successfully created a new user account. The remainder of this video shows you how to define user and password policies. Start by clicking Home User Policies. The User Policies page will appear as shown on the screen. Next, configure the password policy to match the one used by your organization. This entails (one) Setting the Password Length. To define the minimum length of the password, select the "Password must have at least" check box, and enter the desired number of characters that the password should contain; (two) select "Password must contain numbers or special characters" if the password should consist of at least one number or special character; (three) if the password should have an expiration date, then select the "Password must expire" check box. Password Expires After checkbox, and enter the desired number of days after which a password is no longer valid. four. To prevent reuse of a password, select the Password Cannot Be Reused Within checkbox, and enter the desired number of days after which the password can be reused. User policies are defined in the User field below. To limit the number of failed logon attempts, select Disable User Account After checkbox and enter the number of permitted logon attempts. This automatically disables the user account after the specified number of unsuccessful logon attempts. Finally, user accounts can be locked after a certain period of inactivity by selecting the Lock User Account After (checkbox): Specify the number of minutes after which the user account should automatically lock, thus requiring a new log in. Click file; save. Setting up unique user accounts is quick and easy in Star e Software. This fulfills a basic requirement of twenty one c f r part eleven. Namely, that all work is attributable to specific individuals. Additionally, password and user policies can be defined according to the security requirements of your organization. For more T.A.-related how-to videos, please go to www.mt .com forward slash T .A. dash videos.
The CFR option provides the mandatory technical controls for compliance with 21 CFR Part 11 regulations on access control, user level management, electronic records, electronic signatures, and audit trail. Star E enables access control to the application, user level management, electronic signatures, and audit trails. User level management is part two of a series of four how-to videos, teaching you how to make best use of the Star-E CFR option for data integrity. The User Rights option in Star-E software reduces the risk of data manipulation by restricting users to areas of the system that allow them to perform their job functions. The system administrator can grant up to 30 different rights to an unlimited number of user roles or profiles. Example, administrator, lab manager, lab technician, and so on. In this video, we show you how to create new user roles to which you can assign any number of the available access rights. For this, you need to have administrator rights. Under the Home tab in the Install window, click on... USER ROLES From the left box listing the available rights, select the privileges you wish to assign to the user, and move them to the assigned rights box using the arrow button pointing to the right. Click FILE SAVE In the dialog box, add the name of the role (for example, Lab Technician). and click OK. In regulated environments, each user must also be assigned a signature level corresponding to their job functions. First, you need to provide appropriate meanings to the different signature levels. In the install window, click on Home, Meanings of signatures. Select up to 10 levels and assign a meaning to each. For example, Level 1. CHESTED-Level four-Reviewed. Level seven-Approved. And-Level ten-Released. Click File, Save. So far we have created a user role and four signature levels, which can be assigned to individual users on the User Accounts page. Click Home > User Accounts. The User Accounts page appears. In this example, we are creating an account for Michael Fraser. After entering the user's personal details (as shown in part one), choose a role from the drop down menu, in this case, Lab Technician. Then in the field just below select the appropriate signature level, for instance, Tested, from the drop down list. Click FILE SAVE. The User Role Lab Technician with a signature level tested is now assigned to Fraser. Recommended signature levels for different roles are given in the table. Once a user has signed a record, it can only be signed again by another user and with the same signature level or higher. In other words, if Miller signs a record, it can only be signed by Widman or Jones, who have signature levels seven or ten. Thanks to the user rights option in Star eSoftware, 30 different privileges and up to 10 signature levels can be allocated as appropriate to an unlimited number of user roles. For more TA-related how-to videos, please go to www.mt .com forward slash ta-videos.
Part 2: User Rights
Managing user rights in the STARe software reduces the risk of data manipulation by restricting users to areas of the system that allow them to perform their job functions. Part 2 of the video series covers this topic and mentions how to best use the STARe 21 CFR 11 software option for data integrity in thermal analysis.
This video shows you how to create new user roles, to which you can assign any number of available access rights to an employee.
Part 3: Electronic Signatures
Electronic signatures in STARe software meet the requirements of 21 CFR Part 11 to ensure secure access to original data, which cannot be removed, copied or transferred. Part 3 of the video series covers the topic of how to best use the STARe 21 CFR 11 software option for data integrity in thermal analysis.
This video shows you how to assign electronic signatures to data records in STARe software.
The c f r option provides the mandatory technical controls for compliance with twenty one c f r part eleven regulations on access control, user level management, electronic records, electronic signatures, and audit trail. Star e enables access control to the application, user level management, electronic signatures, and Audit Trails The use of electronic signatures is part three of a series of four how -to videos teaching you how to make best use of the Star E CFR option for data integrity. Electronic signatures ensure secure access to original data which cannot be removed, copied or transferred. Part 3 of this series details the process of assigning electronic signatures to data records in Star-E software. The remainder of this video guides you through the procedure of defining electronic signatures for data records. To know who has previously signed an existing curve, click Signatures on Curve under the File tab. Similarly, to view signatures for an existing evaluation, click Signatures on Evaluation. The Signatures dialog box appears, showing individual signatures for the selected curve or evaluation, their meaning-such as Tested or Reviewed-the date and time the record was signed, and any additional remarks. To sign an existing curve or evaluation, click File, Sign Curve; or File, Sign Evaluation, as applicable. The electronic signature dialog box will appear on the screen; in this example, the "User Name" Miller is automatically included in the user name field. Enter the user's password, and in the "Meaning of Signature" field, enter the meaning of the signature. Select the appropriate meaning from the drop down menu, in this case Reviewed. Add any additional comments to the Remarks box and then click OK to append the signature to the record. The preceding signature remained linked to the record and can be viewed with the Signatures on Evaluation commands in the File tab. In paper printouts of electronic records: Each page and plot is marked as either signed or unsigned; in addition the last page contains the first name, last names, user names, meanings and remarks for each signature applied. Electronic signatures and star e software meet the requirements of twenty one c f r Part Eleven. For more t a related how to videos, please go to www.mt .com forward slash t a dash videos.
The c f r option provides the mandatory technical controls for compliance with twenty one c f r Part eleven regulations on: access control, user level management, electronic records, electronic signatures, and audit trail. Star e enables access control to the application, user level management, electronic signatures, and audit trails. Part 4 of this series demonstrates how to activate and review audit trails in Star E software. An audit trail is a chronology of the who, what, when, and why for a specific data record. The built-in audit trail functionality in Star E software generates complete audit trail entries, which include links to the corresponding records. User ids -original and new values; reasons for change; date and time stamps. Upon activating the c f r option, the system and analysis audit trails are permanently switched on. No user has the ability to amend or switch off the audit trail. The System Audit Trail and Analysis Audit Trail can be found in the main menu bar once the 21 CFR Part 11 compliance option has been successfully installed. Click on the relevant icon to view the system audit trail. The audit log contains data entries for all past activities relating to the system. These include starting the software, user logins, and any changes made to the system configuration. Useful filter criteria also allow you to limit your search to specific actions, users and timeframes. For example, from the drop-down menu, select the action Star E Software Startup. The username Miller. And key in the date after which you would like to view the entries. In this case, all data entries prior to the inserted date will be excluded from the list. Finally, click Update to display all entries corresponding to the specified criteria. To print the selected audit trail entries, click Print and confirm with OK. It is also possible to export the audit trail in text format. Simply click Export key in the File name and save it in the preferred location. Select the Analysis Audit trail to view all entries that have to do with the analysis of samples. For example, Jones Ronald signed the evaluation p e t on the twenty ninth of august two thousand eighteen at seven minutes and seven seconds past eleven. In this example, Jones Ronald is the user signing the record as an action, the evaluation is the record type and p e t is the record name. The Filter Criteria option allows you to filter by: Action Username, date, or date range and record type. Once you have made your selection, click Update to view the refined list of entries. The CFR option in Mettler Toledo's Star eSoftware provides complete, secure and easy-to-navigate audit trails that meet Part 11 requirements for technical controls. For more T_A_ related how-to videos, please go to www.mt .com forward slash T_A_ dash videos.
Part 4: Audit Trail
The built-in audit trail functionality in STARe software generates complete audit trail entries, which include:
- Links to the corresponding records
- User IDs
- Original and new values
- Reasons for change
- Date and time stamps
Part 4 of the series is on how to make the best use of the STARe 21 CFR 11 software option for data integrity in thermal analysis. This video shows you how to activate and review audit trails in STARe software.