SmartCheck Takes Less than 60 Seconds

A pipette verification device saves time and money by verifying the performance of a pipette before working with precious samples or reagents. SmartCheck™ is the only benchtop pipette volume verification device capable of determining if a pipette is dispensing accurately in less than 60 seconds. Compact by design, SmartCheck reduces the risk of experimental failure.

Call for Quote
View Results ()
Filter ()

Add 1 or 2 more products to compare

Advantages of SmartCheck Pipette Verification

Reliable Pipette Verification

With SmartCheck, pipette verification is simple: Just choose one of SmartCheck's pre-set volumes that are within the operating range of the pipette and dispense that volume into the vessel. After automatically detecting the volume, SmartCheck prompts you to dispense the same volume three more times. SmartCheck runs a number of calculations, and then clearly indicates pass or fail.

SmartCheck

How Does SmartCheck Work?

Not only is SmartCheck fast – it's the only automatic ISO 8655-based pipette verification tool available. SmartCheck takes volumetric measurements using the gravimetric method and calculates the random and systematic error based on four measurements. It then determines the measurement uncertainty of the delivered volume in percentages, comparing it to the pipetting tolerance in percentages, yielding a quick pass or fail statement of the instrument and user within 60 seconds.

SmartCheck

Verify Any Brand of Pipette

Use SmartCheck to verify the performance of any brand of pipette that dispenses volumes between 10–1000 μL. Verify individual channels of multichannel pipettes too. It's simple: dispense deionized water into the liquid chamber and SmartCheck automatically detects the test volume, then prompts you to dispense the same volume three more times. From start to finish, SmartCheck delivers a pass/fail result in less than 60 seconds. This compact device is also perfect for training and improving pipetting technique.

Documents

smartcheck data sheet
Download the SmartCheck™ data sheet to learn more about a fast, practical way to verify that a pipette is dispensing accurately between calibrations.
SmartCheck User Guide
SmartCheckTM is a pipette check instrument. It may be used for single channel or multichannel pipettes. The intended use is to check if a pipette`s...
SmartCheck FAQ
These SmartCheck focused questions and answers are organized into four main topics: purpose and usage; tolerances and ISO8655; maintenance and calibra...
800 472 4646 (800 4 RAININ)
Call Service

Expert Service – Tailored to Fit Your Pipetting Needs

METTLER TOLEDO supports and services your pipettes through their entire life-cycle, from good pipetting techniques to preventive maintenance and calibration to equipment repair.

Uptime
Support & Repair
Performance
Maintenance & Optimization
Compliance
Calibration & Quality
Expertise
Training & Consulting

Pipette Verification Is Simple with SmartCheck

Verifying the performance of a pipette before working with precious samples or reagents saves time and money. In less than 60 seconds you will know if...

Verifying the performance of a pipette before working with precious samples or reagents saves time and money. In less than 60 seconds you will know if a pipette is aspirating and dispensing correctly. Between calibrations, SmartCheck provides a fast, practical way to verify that a pipette is dispensing accurately and provides reassurance that the pipette you are using is performing as expected.


FAQs

What is pipette verification?

Pipette verification allows the user to determine if the pipette is dispensing accurately before starting an experiment. Regular pipette calibration and preventative maintenance can significantly reduce the costs, risks, and liabilities associated with out-of-calibration pipettes. However, in-between calibration intervals failures and out-of-tolerance issues can arise. Several factors can compromise the integrity of your pipettes – causing them to deliver incorrect volumes and irreproducible results.

What is SmartCheck?

SmartCheck is a new verification technology from Rainin that allows life science researchers to verify the performance of their pipettes right at the bench. It takes just 60 seconds to know whether a pipette is accurate or not. Quickly and easily verify the accuracy of your pipetting prior to critical experiments.

What does SmartCheck do?

SmartCheck provides a fast, practical way to verify that a pipette is dispensing accurately and reduce the risk of experimental failure. It may be used to verify single channel or individual channels of a multichannel pipette. 

How often should you verify your pipette with SmartCheck?

  • Every day before the start of a key experiment
  • When pipetting precious samples or reagents on a regular basis
  • When experimental workflows are complex and time-consuming
  • When you have inexperienced users and/or it is unclear if the pipette or user is causing inconsistent results
  • After your pipettes have been used by another researcher
  • When you would like to use a pipette that has not been used or calibrated in a while

Does SmartCheck replace pipette calibration or maintenance?

SmartCheck does not replace regular pipette calibration and maintenance. Rainin recommends verifying every pipette at least once a month. Regular verification helps ensure consistent, accurate pipetting in between scheduled pipette calibrations or maintenance.

What is the difference between verifying your pipette with SmartCheck vs. using an analytical balance?

Both devices use the gravimetric principle and have a weighing cell, but the comparison ends there. SmartCheck uses an advanced load cell technology that is designed to be fast, simple and very robust. SmartCheck automatically performs ISO 8655-based calculations and delivers a clear pass/fail result. Balances only deliver absolute values that need to be converted, calculated and require a high level of skill and technique.

Which pipette brands can be verified with SmartCheck?