Routine testing of balances and scales by the user is essential to uncover malfunctions early and eliminate inaccuracies that would otherwise go undetected until your next service calibration. More and more users are realizing that it is both less expensive and more efficient to build quality into weighing results from the start, rather than discovering problems later on.
The 4 Pillars of Routine Balance and Scale Testing
Our short guide explains the four pillars of successful weighing device testing:
Test frequency
Test methods
Test weights
Test tolerances
Download the Guide
The guide provides easy-to-follow material which outlines how often to test, how to test and which weights to use to ensure proper balance function. Furthermore, links to helpful tools and complementary information are provided.
Put Routine Testing into Practice
It pays off to build quality into weighing results from the start, rather than discovering problems later on. Put routine testing into practice and ensure your weighing results are accurate each and every day.
Why Is Routine Testing of Balances and Scales So Important?
Balances and scales play a critical role in research, development, quality assurance and production. However, errors in weight measurements cost time and money, and violations of legal requirements may even cause damage to health and/or the environment. Maintaining and ensuring the performance of a device and reducing the risk of it being outside process tolerances requires the correct setup of the instrument and regular calibration by the service provider. Between service intervals, the user should perform regular routine tests to uncover malfunctions early and eliminate surprises at the next calibration service.
In many cases, defining routine test frequencies, adequate procedures and proper staff training can be a challenging and time consuming task, tying up valuable resources.
Are you sure your balance or scale is performing as it should? Could you document its performance if you had to? In this video, we'll talk about the routine testing of your balance or scale. You'll learn what routine testing is, why it's necessary, and how to do it right. First, let's look at what routine testing actually is. Imagine your balance or scale is a car. As a responsible car owner, you have regularly scheduled service appointments with a mechanic to help keep your car running well. Are you sure your weighing equipment is performing as it should? Could you document it if you need to? In this video by METTLER TOLEDO, you will learn about the routine testing of balances or scales and the answers to common questions such as: What is routine testing? Why is it necessary? How can it be done correctly? Over time, the performance of your weighing device can change. By testing routinely, you can make sure your weighing results remain accurate. Learn more about how to perform successful routine testing. Click the link below to find out more about GWP-Verification: https://www.mt.com/global/en/home/library/laboratory-weighing/Good-Weighing-Practice/verification-of-good-weighing.html?cmp=smo_GLO_YT_LAB_OTH_Youtube_LAB_zs3Y0w0hh3w Over time, the performance of your weighing device can change due to environmental influences, wear and tear, and other damage that's not visible. Routine testing checks to ensure that the device continues to perform accurately enough based on your needs until your next calibration. What is the right way to test a weighing device? There are four pillars that influence the routine testing of any weighing device. They are test frequency, test methods, test weights, and test tolerances. User training is also a key factor and forms the basis for the success of your routine testing program. First, let's take a closer look at what test frequency entails. How often do you need to perform your tests? The frequency will increase depending on the risks that are a part of your weighing process and how those risks could affect results. If the risk to accuracy, your process, or your product quality is high, you will need to perform testing more frequently. The second pillar involves your test methods. To verify the performance of your weighing device, there are three different tests that need to be run. Sensitivity tests are quick and simple. Sensitivity is measured by comparing the indicated value to the reference weight value. This is performed by placing a calibrated test weight on your balance or scale. The repeatability test checks the ability of a balance or scale to supply the same result with repeated weighings using the same load under the same conditions. It's usually measured by 6 to 10 consecutive measurements. A standard deviation is then calculated. Repeatability tests are usually done less frequently than sensitivity tests. However, they are important, especially when measuring small samples. The eccentricity test checks the corners of your balance or scale. Is there a difference in the indicated weight depending on where you place the load on the weighing pan? For each of these three tests, we offer SOPs, standard operating procedures, that you can download for free. They guide you through each of these test methods in detail. You learn how to perform these tests and assess the results. Now, let's look at the third pillar, choosing and using correct test weights based on your device, your process, and standard operating procedures. Good weighing practice, Mettler Toledo's global weighing standard, specifies that you only need two test weights for the routine testing of a balance or scale. This reduced requirement can simplify and optimize your testing efforts, while saving you a considerable amount of time and money. A smaller weight is needed for repeatability tests, typically about 5% of your device's capacity, and a larger weight is needed for sensitivity and eccentricity tests. And finally, let's review test tolerances, the fourth pillar of an effective balance testing program. Routine testing tells you whether or not your balance or scale is performing accurately enough. To have a clear pass or fail result, you need to define testing tolerances. GWP offers three levels of performance verification based on the concept of tolerance. The first level, in green, means the device performs within your predefined tolerances. The second level is a warning limit. This indication in yellow means that the device is not out of tolerance yet, but the safety margin has decreased. The balance or scale can still be used, but Mettler Toledo should be contacted. The control limit in red specifies when the device is out of tolerance and no longer fit for purpose. In this case, the balance or scale must be taken out of operation. Contact Mettler Toledo for a calibration and to assess the next steps. Keep in mind that the results of your routine testing depend on proper user training. This essential component should also be documented for audit purposes. Congratulations! You're now familiar with the four pillars of a robust and effective routine testing program. If you need help determining your necessary test frequency, which tests you should perform, and which weights you should use, Good Weighing Practice offers the GWP Verification Service. This easy-to-apply service answers these questions for your specific case, based on your requirements and your assessed risk. On selected Mettler Toledo weighing devices, a routine testing program is pre-installed. For more information on whether these devices are right for your process, contact us. Thank you for watching. We hope we can support you as you work to achieve accurate weighing results.
How to Make Sure You Are Not Testing Too Often or Too Little?
Daily routine testing of balances and scales at multiple points in the operating weighing range can take a great deal of time and effort, and may not even provide any meaningful metrological information. The recommended frequency of routine testing for any given balance and scale depends on the risk and consequences of inaccurate results for the business, and/or health risks for users, combined with the ability to trace back errors. The risk of inaccurate results can be assessed by answering the following questions:
Business impact: What is the impact of wrong or inaccurate weighing results on your business process? Consider the loss of material and time, out-of-specification results, rework, production downtime, fines, product recalls, unhappy customers, loss of reputation, etc.
Consumer impact: What is the impact of wrong or inaccurate weighing results on people, animals, or the environment?
Probability of detection: Is there a chance of detecting a wrong or inaccurate weighing result immediately and easily?
Discover in the guide what is really essential for testing your balance and scale and get tips on designing test frequencies that are reasonable and appropriate.
Test Methods, Warning and Control Limits
Routine tests may include sensitivity, repeatability and eccentricity tests using appropriate calibrated test weights. Tolerances or warning and control limits depend on the weighing tolerance for the process in question. Warning limits indicate when a device is nearing an out-of-specification condition. Control limits alert you when the device is no longer deemed fit for purpose.
Routine testing of balances and scales between scheduled calibrations helps to maintain accuracy by ensuring early detection of non-compliance with weighing process requirements so that corrective action can be taken in a timely manner.