Transmitter M100 SM RS-485

For Analog or Digital Biocontrollers The M100 Sensor Mount (SM) is a single-channel transmitter for connecting ISM optical dissolved oxygen sensors to a biocontroller. The Bluetooth 4.0 interface is compatible with the PC-based and mobile versions of iSense software.

Straight-forward Connectivity

The M100 SM offers multiple independent interfaces: two configurable 4/20 mA analog outputs and one digital MODBUS RTU.

Clear Sensor Status Alerts

LEDs clearly indicate sensor status, alarms and warnings to ensure your sensor is working properly.

Easy Sensor Handling

ISM’s Plug and Measure feature minimizes the risk of installation trouble and simplifies sensor handling.

M100 Sensor Mount Transmitter RS485
Zadzwoń
Dane techniczne - Transmitter M100 SM RS-485
Rodzina modeli M100 SM
Parametry pomiarów Optical DO
Channels 1
Typ czujnika ISM
Wymiary Sensor Mount
Zasilanie 24 VDC
Wyjścia prądowe 2 x 0/4-20mA
Przekaźniki None
Digital input None
Analog input None
Regulator PID None
User Interface None
Interfejs USB No
Stopień ochrony IP67
Komunikacja Bluetooth; MODBUS RTU
Wiring Mode 4-Wire
Dopuszczenie do użytkowania w strefach Ex No
Hygienic/Biocompatibility Approvals No
Other certificates CE compliant
Primary Media/Application Pharmaceutical/Life Science Production; Other Industrial Processes
Numer(y) materiału 30365367

Simplified installation
The M100 SM is an easy to install, sensor mount transmitter for the analog or digital integration of ISM optical dissolved oxygen sensors into a biocontroller‘s programmable logic controller.

Predictive maintenance
iSense Mobile and Bluetooth communication provide access at any time to ISM‘s predictive maintenance diagnostics. Diagnostics and other sensor data can be sent as an email from a mobile device.

Error-free operation
Transmitter current outputs are configurable via PC or mobile device. Reconfiguring is not necessary after a sensor exchange, eliminating configuration errors.

Electronic data management
Configuration and calibration data are stored on the sensor. Wireless communication allows this information to be sent to iSense where it can be used for sensor management and compliance purposes.

Dokumentacja

Datasheets & Brochures

Datasheets for Sensor Mount Transmitter M100 SM
The M100 Sensor Mount (SM) is a single-channel transmitter. It allows the connection on biocontrollers of 1-wire ISM sensors for measuring pH, ampDO a...

Instruction Manuals

Instruction Manuals for Sensor Mount Transmitter M100 SM
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits ar...
Application Solutions for M100 Modbus Programmers Guide
This programmers guides explains general modbus informations, implemented modbus registers in M100, detailed description of the implemented Modbus re...

Bus Communication Info

M100 2XH DTM Setup V1.00.0003
HART, DTM for PACTware ™: Version 4.x

Videos

Pierwszy na świecie przetwornik głowicowy do pomiarów analitycznych
Obejrzyj film prezentujący, jak łatwo można przeprowadzić analizę in-situ, posługując się przetwornikiem głowicowym M100.

Akcesoria

Proszę o ofertę na
Transmitter M100 SM RS-485
Hazardous Area
FM Approved
FDA