The engineering guidelines also include critical information such as:
Our Weigh Module Systems Handbook provides scientific data and details critical guidelines to help you design an accurate, reliable weighing system. With more than 150 fact-filled pages, the Handbook helps you select and apply weigh modules to create high-performance weighing or inventory control systems. This is the most thorough handbook available for designing tank-based weighing systems for the industrial market and is perfect for professionals in engineering, operations, or integration.
- Assessing your tank, platform, or conveyor system performance needs and setting specific performance criteria.
- Engineering calculations that account for the effects of wind, seismic, shock, thermal effects, and load cell cables.
- Creating tank piping-connection designs in the context of support structure and foundation.
- Qualification guidelines for structural, foundation, electrical, and mechanical considerations to ensure best accuracy.
- A complete set of engineering specifications for compression load cell, tension load cell, static load cell, and dynamic load cell applications.
- How calibration, verification, and service help to ensure long-term tank scale performance and system uptime.
- Types of load cell technology available for weighing systems and why certain load cell technology types are better than others.
- How load cell cable length influences the reading of a tank scale.
- Common specifications such as load cell accuracy and load cell material types.
- Tools such as a load cell accuracy calculation and a load cell capacity calculation.
Load Advisor simplifies your job when commissioning and managing tank scale systems by offering guided setup and advanced condition monitoring. Let's see how it works. The PowerCell system is easy to wire. Conveniently access Load Advisor by selecting the soft key located on the main application screen. This brings up the tank visualization and begins the guided setup procedure. First, execute the load cell addressing. Here you will configure the capacity and increment. As well as the tank layout, map the physical layout of the weigh modules to the screen visualization for easy diagnostics. This can be done by serial number or simply by loading each weigh module to identify its position. If shimming is required to level the system, Load Advisor will highlight the weigh module to be shimmed. To ensure the highest accuracy, follow the guided electronic shift adjustment. As a last step, select your desired method for adjustment. Now you get a qualified and ready to use tank. During operation, IND360 Tank Vessel offers live condition monitoring and alerts you in case of an issue. Alarms are categorized into five levels according to SMART 5, separating low and high priority alarms. In case of a load cell error, Load Advisor's visualization lets you immediately locate the issue. While run flat approximates the weight value to sustain operation while you plan for a fix. For a routine check, leverage the comprehensive locally available data such as load distribution, center of gravity, and load cell temperature readings. The center of gravity indication helps you identify an abnormal shift in load caused by material sticking to side of the tank, blocked load cells, or piping issues. With full visibility to the system status, blind spots are eliminated and you can safeguard weighing performance. Leverage the power of Load Advisor to simplify your job with the IMD 360 panel. Ideal for installation into a control cabinet or with IND360 harsh with IP69K protection.
Hello, my name is Ferenc Muranyi. I'm product manager for weighing components at Mettler Toledo. Having confidence in your weighing system for your production batches is critical to ensure high quality products. Downtime is not an option. Right at first time, batches are a must in the chemical industry. Our PowerCell technology and the diagnostic functions help to avoid errors or inaccuracies which could potentially lead to poor product quality or, in the worst case, recalls and claims. Let me demonstrate the key functionalities of our PowerCell technology with this demo tank. At the bottom, we mounted traditional old school analog load cells. On the top, we mounted our PowerCell technology. You might ask, what are the key differences between analog systems and our PowerCell technology? There are many, but today I will cover the top five. The first four functions alert you about the following conditions: missing or failing load cell, out of range temperature, overload of a single load cell, and a symmetry error. If any of these events occur, we have the fifth function in our PowerCell technology, the RunFlat. That will make sure that your weighing system is running even in the case of error. Firstly, I will demonstrate how the system alerts you about a missing or malfunctioning load cell. Of course, we assume everything runs as intended, but remember, it takes only one failure to result in irreversible consequences of a production batch. In an analog system, the weighing terminal receives the sum of the signals coming from the load cells. Without any further information about the status of the scale, but in a power cell system, each load cell transmits the weighing result and the status information. In contrast to power cell system, in an analog system, the component failure is not apparent to the operator or to the control system, which could lead to out of spec results. Using power cell technology, this won't happen. Let me now demonstrate what happens when a load cell completely fails. To show that, I will cut the cable of an analog load cell and of a PowerCell load cell, and we will see how the system is affected. On the terminal's display, you see the analog weight value at the bottom and the PowerCell value on the top. Now I cut the analog cable. You see a significant change in the indicated weight. But you can't tell if this value is true or not. So a broken load cell goes completely undetected. Now I'm cutting the power cell cable, and you see a totally different result displayed on the terminal. In this case, the user and the control system are alarmed, and they can react before any real problems occur. Each power cell contains a temperature sensor which detects when the temperature is out of range. For example, if exceptionally hot material is in the tank or nearby, you are immediately alerted about potential measurement errors. Each power cell load cell also self-monitors to tell you when the load is too heavy or has a run-in with heavy equipment. This self-monitoring tells you about potential reduction in accuracy and in the worst case, damage of the load cell or components within the scale. PowerCell load cells constantly monitor themselves for internal defects, such as broken wires, leakage, and sufficient wattage supply. If anything is amiss, you will receive an alarm to prevent costly production errors. In a tank scale, the center of gravity typically stays in a small horizontal range and mostly shifts vertically with loading. Let's assume material slowly collects on one side, leading to negative consequences in your production. This collection of material shifts the center of gravity one side and is detected by the terminal as an error condition. The same would happen when a tank leg breaks, the foundation loosens, or a blockage develops. Thus, symmetry monitoring is a form of condition monitoring that lets you react before trouble gets there first. Again, this is not possible with an analog system. We have talked about the condition monitoring that the PowerCell-based system delivers. If you see a rare failure of a PowerCell scale, you have the option to stop production or use the automatic run-flat function. Similar to car tires, run-flat allows you to drive slowly until the tire can be replaced in the next repair shop. The terminal emulates the faulty load cell, so manufacturing can continue, with a lower accuracy of course. That ensures a smooth transition until the problem is solved. Now I cut the power cell load cell cable again, and then you see a much better outcome. The run flat function is activated, so the terminal continues weighing, including a clear status indication that it is in a less accurate state. Again, this safety feature is not available in analog systems. All the PowerCell functions help to avoid undetected failures that lead to production problems and even to product recalls. So when quality is important and uptime is important, consider our PowerMount weigh modules with the built-in PowerCell technology. And now, the clear winner is PowerCell.
Successful integration of sensors into machines requires expertise to assimilate everything into a system. A 100% plug and weigh device gives you the ability to safely and easily integrate weights and control. What if beyond 100 %? At the point of startup, you will receive 100% accurate and reliable weight with local approvals based on industry standards, including globally recognized documentation based on your exact requirements. A 100% competitive edge comes through faster network data improving your machine's performance for higher throughput. Achieve 100 % reliability through smart sensors and condition monitoring that notify your customers when action is required. Thousands of factory-trained service specialists worldwide are available for calibration, adjustment, approval and startup. Plug and weigh connectivity available for any capacity. Saves you valuable engineering hours during design, implementation and factory acceptance with access to thousands of weighing experts. Eliminates your start-up headaches 100 % of the time.
Is designing and engineering tanks, silos or bioreactors your company's business? What if you could easily amplify the value you deliver to your customers and boost their operations? Regardless of vessel shape or material type, weighing remains one of the most accurate inventory control methods available. Implementing this method is even easier with the IND360 Tank Vessel Automation Weight Indicator. Here's why. Save hours of developing and testing your own tank weighing application and take advantage of built-in automatic refill and versatile automation network connectivity. With the IND360 you get a device designed for easy integration into major automation systems and you can conveniently configure and monitor your system from anywhere with the web interface. But what if something goes wrong? The IND 360 offers condition monitoring and alarms, allowing you to react quickly and keep the system operating at peak performance. Oh, one more thing. It's designed with flexibility in mind. The IND 360 connects to scales and sensors of all types and capacities, allowing you to make the best of your system. Learn more at www.nt .com slash ind360.
This is a Mettler Toledo weight sensor. This is a Mettler Toledo weigh module. And this is a Mettler Toledo transmitter. They all exceed the highest industrial requirements, something you can't see from the outside. We produce sensors, scales, and weighing electronics for your production machinery that are based on simplicity. And as simple as Mettler Toledo solutions look, they are even simpler to integrate. The components have been designed to be easily and flexibly combined with your production machines. Plug and communicate. Using intelligent connectivity, these precision instruments deliver impressive performance, and all the while requiring a minimum amount of physical space. Here is a small comparison. The true size is in the details. The sensors feed up to 1,200 high-precision measurements per second. And because you need to rely on each and every one of these measurements, the last measurement is as precise as the first. Just one more thing that can't be seen from the outside. What you will see, simply, is measurable success. More information can be found at www.mt.com.
![]() |
Weigh Module Spotlight
One of the load cell technologies featured in the handbook is METTLER TOLEDO’s PowerMount™ weigh modules with POWERCELL® load cell technology. This load cell technology offers active condition monitoring to improve Overall Equipment Efficiency (OEE), identifying variances before they impact productivity. This allows manufacturers to maintain process control and avoid mistakes before they cost money.
Learn More
Learn More
Without the kind of continuous monitoring offered by POWERCELL® technology, errors such as load cell overload, poor communication caused by damaged load cell cables between modules, out-of-symmetry errors, and out-of-range temperatures can go unnoticed for long periods. When they do, out-of-specification batches and poor-quality products are the result.
PowerMount™, equipped with POWERCELL® load cell technology with onboard microprocessors, not only alerts operators to performance degradation — they also adjust the weighing signal to compensate for environmental changes. This allows PowerMount™ weigh modules to provide accurate weighing regardless of the effects of temperature, linearity, hysteresis, and creep. In the unlikely event of a load cell failure, the design of PowerMount™ also makes individual load cells easy to replace.
FAQ
What is a load cell cable?
What is a load cell cable?
On multi-load cell systems each load cell is connected by a load cell cable to a junction box, which adds the individual load cell signals together to provide one signal that can be transmitted to the indicator. Analog is the most common operating mode, but some scale suppliers offer proprietary and non-proprietary digital operating systems. When using a digital system, consult the supplier’s technical manual for proper junction box wiring.
Normally, each load cell is supplied with a standard length of cable. Do not lengthen or shorten load cell cables in the field. Changing the length of a load cell cable will affect the output signal from the load cell. If a cable is too long, simply coil the excess cable and place it in or near the junction box. You can order junction boxes in sizes that are large enough to hold coiled cables. Never attach excess cable to a live portion of the weighing system. Nonstandard lengths of cable can be ordered for applications that require them.
How do I connect a load cell? How do I connect multiple load cells in parallel?
How do I connect a load cell? How do I connect multiple load cells in parallel?
A load cell cable is used to connect the load cell to the terminal (a system with just one load cell) or to a junction box (a system with more than one load cell / multiple load cells in parallel). On analog load cells this cable is usually an integral part of the load cell. Our Engineering Handbook offers insight on how to connect a load cell and how to connect 4 load cells.
What is the difference between 4 wire and 6 wire load cell?
What is the difference between 4 wire and 6 wire load cell?
6-wire load cells have additional voltage sensing lines as part of the load cell's circuit; 4-wire load cells do not. The additional 2 wires in a 6-wire load cell allow terminals designed for the system to maintain the ideal voltage. This improves the system performance compared to systems with 4-wire load cells, especially in applications where the terminal is further from the scale.
How do I install a load cell? How do I mount a load cell?
How do I install a load cell? How do I mount a load cell?
Our Engineering Handbook provides general information about how to install a load cell or weigh module and tips on proper load cell mounting and load cell mounting design. Each application has unique requirements and should be planned by a qualified structural engineer. When installing load cells or weigh modules, refer to the Installation and Service Manual for the specific model to ensure proper load cell mounting and load cell mounting design. This is the best resource for learning how to install a load cell.
How do I manage compression load cell installation?
How do I manage compression load cell installation?
Compression load cells and compression weigh modules are suitable for most weighing applications. These modules can be attached directly to the floor, piers, or structural beams. The tank or other object is mounted on top of the weigh modules. For proper compression load cell installation, consult the Installation and Service manual for the specific model. Our free Engineering Handbook also offers tips on compression load cell installation.
How do I learn how to wire a load cell? Where do I find a load cell wiring guide or load cell wiring diagram?
How do I learn how to wire a load cell? Where do I find a load cell wiring guide or load cell wiring diagram?
There are many different considerations for how to wire a load cell. On multi-load cell systems each load cell is connected by cable to a junction box, which adds the individual load cell signals together to provide one signal that can be transmitted to the indicator. Analog is the most common operating mode, but some scale suppliers offer proprietary and non-proprietary digital operating systems. When using a digital system, consult the supplier’s technical manual for proper junction box wiring and a load cell wiring guide or load cell wiring diagram.
Our Engineering Handbook offers general information on how to wire a load cell, as well as load cell wiring diagrams for analog or smart weighing systems.
Where can I find a load cell application guide?
Where can I find a load cell application guide?
A load cell application guide helps you match your requirements to the appropriate load cell design. When selecting weigh modules for an application, it is important to consider how the load will be applied to the load cells. Most weigh module applications on tanks, hoppers, and vessels are subject to static loading. Under normal operation with static loading, little or no horizontal shear force is transmitted to the load cells. Applications such as conveyors, pipe racks, mechanical scale conversions, and high-powered mixers or blenders are subject to dynamic loading. With dynamic loading, the way in which products are placed on a scale or processed transmits horizontal shear forces to the load cells. Our free Engineering Handbook offers a load cell application guide, which explains how to select the appropriate load cell or weigh module for your weighing need.
How to convert a load cell reading into total weight?
How to convert a load cell reading into total weight?
Most weighing systems use an analog junction box, which requires an analog-compatible indicator. An analog junction box can sum up to four load cells, acting as a load cell reader. For weigh module systems with more than four load cells, you will need to connect several junction boxes together. Our Engineering Handbook provides more details on how to connect a load cell for accurate weights.
How is load cell accuracy calculated?
How is load cell accuracy calculated?
The load cell accuracy calculation is complicated. There are a number of electronic and mechanical tests that are performed in accordance with a number of metrological a/o commercial standards (as well as basic industry standards), but the basic theory is this: a thin wire network (strain gauge) is bonded to a piece of metal and change in electrical properties when the metal is bent is monitored. Metal has to bend in a repeatable way, the gauge (the wire network) has to report it as signal in a repeatable way, and the terminal must interpret the signal as weight. When we place a reference weight, we tell the terminal that the change in signal is proportional to the change in loading.
What is load cell capacity?
What is load cell capacity?
Load cell capacity is the maximum amount of weight a load cell can bare while providing accurate weight readings and without being damaged. Knowing the load cell capacity will impact your load cell accuracy for any weighing application.
How do you determine load cell capacity? How do you calculate load cell capacity?
How do you determine load cell capacity? How do you calculate load cell capacity?
A load cell capacity calculation contains many components. The load cell is a sensor that must cover the largest and smallest measurement required of it. More specifically, it must not break when maximum load is applied, and it must be able to make the smallest measurement requested of it. In the case of weigh modules, which are load cells plus additional engineered hardware designed to optimize load introduction and may also have additional structural capabilities, keeping a structure from moving or tipping over may also be desired. In any case, knowing the weights and forces required to maintain structural safety/integrity and complete the required measurements is key to successful recommendation. Most engineers receive training to calculate these forces, and we provide limit values of the forces our modules can withstand, so the choice for selection becomes clear.
Load cells measure both the dead load and the net load of a load cell scale, so this needs to be considered when calculating scale load cell capacity. How the goods are positioned on the scale also matters. Using load cells that are larger than they need to be for a given application is not recommended as accuracy suffers. For scales where the goods are mostly centered — which is true for most tank, silo and vessel scales — the formula is:
C >= sf*(TDL+SC)/N (eg. tank scales)
For scales with four load cells where the goods are likely to be positioned off-center — which is true for floor, small truck and conveyor scales — the formula is:
C >= sf*(TDL/4 + SC/2) (eg. floor, small vehicle scales, conveyors)
C = LC or Weigh module capacity
TDL = Total dead load
SC = Scale capacity
sf = Safety factor (typically 1.25)