Sodium, Silica and Chloride/Sulfate Analyzers - Overview - METTLER TOLEDO

    Sodium, Silica and Chloride/Sulfate Analyzers

    Reliable, on-line analyzers with automatic calibration

     

    Sodium, Silica and Chloride/Sulfate Analyzers

    The METTLER TOLEDO Thornton 2300Na sodium analyzer, 2800Si silica analyzers and the new 3000CS chloride and sulfate analyzer provide efficient and reliable monitoring of low contaminant concentrations for pure water treatment in microelectronics and power cycle chemistry applications. They use industry-proven technology with innovative approaches to provide assurance of water purity to minimize corrosion and maximize water production.

     
    Chloride/Sulfate Analyzer 3000CS
    Sodium Analyzer
    Silica Analyzer

    Chloride/Sulfate Analyzer

    Sodium Analyzer

    Silica Analyzer

    The Thornton 3000CS analyzer provides trace level detection of chlorides and sulfates to control corrosion and minimize damage.
    The Thornton 2300Na Sodium Analyzer provides assurance of water purity to minimize corrosion and maximize water production.
    The Thornton 2800Si Silica Analyzer is a reliable on-line instrument designed for pure water treatment and power cycle chemistry.
    On-line measurements every 45 minutes
    for continuous monitoring
    Grab sample capability
    for additional samples or QC checks
    Automatic calibration
    Provides reliable measurement while saving technician time
    Full enclosure
    to protect components and reagents
    Fully automatic, unattended calibration
    ensures reliable operation while saving technician time
    Automated electrode conditioning
    minimizes need for manual etching
    pH Check for proper reagent addition
    Low reagent consumption
    saves reagent costs and handling issues
    Fully automatic, unattended calibration provides excellent repeatability
    while saving technician time
    Low maintenance large reagent bottles
    enable 3 months of operation before refill
    Tests of samples from various locations thanks to
    Grab Sample feature
    Full enclosure to protect reagents
    and components from plant environment
     
     
     
     
     
     
     
    Thank you for visiting www.mt.com. We have tried to optimize your experience while on the site, but we noticed that you are using an older version of a web browser. We would like to let you know that some features on the site may not be available or may not work as nicely as they would on a newer browser version. If you would like to take full advantage of the site, please update your web browser to help improve your experience while browsing www.mt.com.